• 24kV Indoor metal-clad with drawable MV Switchgear
24kV Indoor metal-clad with drawable MV Switchgear
discuss personally
Model
KYN28-24/1250-40
Basic info
Brand ROCKWILL
Model NO. 24KV Indoor metal-clad with drawable MV Switchgear
Rated voltage 24kV
Rated frequency 50/60Hz
Series KYN28-24
Product Detail

Description:

China KYN28 indoor metal-clad with drawable switchgear(hereafter short as swithgear) is a complete power distribution device for 3.6~24KV, 3 phase AC 50Hz, single bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants, power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor,etc, so as to control, protect and monitor the system. The switchgear meets IEC298, GB3906-91. In addition to be used with domestic VS1 vacuum circuit breaker, it can be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc. It is truly a power distribution deviece with good performance.

In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

Service environment:

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  • Altitude no higher than 2500m.

  •  The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

24kV Indoor metal-clad with drawable MV Switchgear.png

What are the technical parameters of indoor metal armored traction medium-voltage switchgear?

Rated Voltage:

  • 24kV: This parameter determines the insulation level and other related electrical performance design criteria for the switchgear.

Rated Current:

  • Common rated current specifications include 630A, 1250A, 1600A, 2000A, 3150A, etc. The specific value should be determined based on the size of the connected load to ensure that the equipment can safely and stably carry and distribute electrical power.

Rated Short-Circuit Breaking Capacity:

  • Typically ranges from 20kA to 31.5kA. This parameter reflects the switchgear's ability to interrupt short-circuit currents. The rated short-circuit breaking capacity must be greater than the maximum possible short-circuit current in the power system to ensure reliable interruption of fault currents during a fault, preventing the accident from escalating and maintaining the safe and stable operation of the power system.

Protection Class:

  • Generally, the protection class is IP4X or higher. The protection class indicates the enclosure's ability to protect against the ingress of external objects and water. An IP4X protection class prevents the entry of solid objects larger than 1.0mm in diameter into the switchgear, as well as accidental entry of foreign objects or tools, thus effectively protecting the normal operation of internal electrical components.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is Transformer Vector Groups?
What is Transformer Vector Groups?
Transformer Vector Group DefinitionThe transformer vector group denotes the phase difference between the primary and secondary sides of a transformer, while also defining the arrangement of high-voltage and low-voltage windings in three-phase transformers. Vector groups are determined by the connection configurations of three-phase transformers, which can be categorized into four main groups based on the phase difference between corresponding line voltages of the high-voltage and low-voltage sid
Edwiin
06/02/2025
What is a Pure Resistive AC Circuit?
What is a Pure Resistive AC Circuit?
Pure Resistive AC CircuitA circuit containing only a pure resistanceR(in ohms) in an AC system is defined as a Pure Resistive AC Circuit, devoid of inductance and capacitance. Alternating current and voltage in such a circuit oscillate bidirectionally, generating a sine wave (sinusoidal waveform). In this configuration, power is dissipated by the resistor, with voltage and current in perfect phase—both reaching their peak values simultaneously. As a passive component, the resistor neither
Edwiin
06/02/2025
What is a Pure Capacitor Circuit?
What is a Pure Capacitor Circuit?
Pure Capacitor CircuitA circuit comprising only a pure capacitor with capacitanceC(measured in farads) is termed a Pure Capacitor Circuit. Capacitors store electrical energy within an electric field, a characteristic known ascapacitance(alternatively referred to as a "condenser"). Structurally, a capacitor consists of two conductive plates separated by a dielectric medium—common dielectric materials include glass, paper, mica, and oxide layers. In an ideal AC capacitor circuit, the current
Edwiin
06/02/2025
Resonant Frequency
Resonant Frequency
In a series circuit, the resonant frequency condition occurs when the inductive reactance equals the capacitive reactance. Changing the supply frequency alters the values of XL = 2πfL and XC = 1/2πfC.As the frequency increases, XL rises whileXC falls. Conversely, a decrease in frequency causesXL to drop andXCto rise.To achieve series resonance, the frequency is tuned to fr(pointP in the curve below), whereXL = XC.At series resonance, when XL = XCWhere frdenotes the resonant frequency in he
Edwiin
06/02/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Mesh Current Analysis Method
Mesh Current Analysis Method
The Mesh Current Analysis Method is utilized to analyze and solve electrical networks with multiple sources or circuits comprising numerous meshes (loops) containing voltage or current sources. Also known as the Loop Current Method, this approach involves assuming a distinct current for each loop and determining the polarities of voltage drops across loop elements based on the assumed direction of the loop current.In mesh current analysis, the unknowns are the currents in different meshes, and t
Edwiin
06/02/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放