• MNS type 380V 660V LV withdrawable switchgear
MNS type 380V 660V LV withdrawable switchgear
discuss personally
Model
MNS-660
MNS-380
Basic info
Brand ROCKWILL
Model NO. MNS type 380V 660V LV withdrawable switchgear
Rated insulation voltage 1000V
Rated current Horizontal bus bar 630-5000A
Rated current Vertical bus bar 800-2000A
Rated working voltage 660V
Series MNS
Product Detail

Description :

MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module through consulting MNS series low voltage switch cabinet of Switzerland ABB Company, and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as control device for various power generation, transmission, distribution, power transfer and power consumption device.

It is widely used in low voltage distribution system of various mining enterprise, tall building and h otel, municipal construction etc. Besides the general land use, after special disposal, it also can be used for marine petrol drill taken platform and nuclear power station. The device accords with international standard IEC439-1 and national standard GB7251.1.

Main feature :

  • Compact design: Contain more function units with less space. 

  • Strong versatility for structure, flexible assembly. C type bar section of 25mm modulus can meet the demands of various structure and type, protection grade and operating environment. 

  •  Adopt standard module design, can be combined into protection, operation, transfer, control, regulation, measurement, indication etc such standard units. User can choose assembly according to requirement at will. Cabinet structure and drawer unit can be formed with more than 200 components. 

  • Fine security: Adopt high strength antiflaming type engineering plastic pack in large quantity to effectively enhance the protective safety performance. 

  • High technical performance: Main parameters reach the advanced level at home.

Main technical parameters:

image.png

image.png

Conditions for normal operating environment:

  • Ambient air temperature: -5℃ ~+40℃  and the average temperature should not exceed +35℃  in 24h.

  • Air condition: With clean air. Relative humidity should not exceed 50% at +40℃  . Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃ . But in view of the temperature change, it is possible that moderate dews will produce casually. 

  •  Altitude above sea level should not exceed 2000M. 

  • The device is suitable to the transportation and store with following temperature :-25℃  ~+55℃  , in short time (within 24h) it reaches +70℃  . Under the limiting temperature, device should not suffer damage that can' t recover, and it can works normally under normal conditions.

  • If the above operating conditions not meet user's demand. Consult with manufactory.

  • Technical agreement should be signed additionally if the device is used for marine petrol drill taken platform and nuclear power station.

Interior structure Diagram:

PC cabinet

image.png

Draw-out type MCC cabinet (Single side operation)

image.png

Q:What is withdrawable switchgear?

A:Withdrawable switchgear is a type of electrical switchgear that allows the circuit breaker and other components to be easily withdrawn from the main body of the switchgear for maintenance, repair or replacement without having to disconnect the entire power supply system. It enhances the flexibility and maintainability of the power system.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Public.
MNS Type LV withdrawable switchgear
Manual English
Consulting
Related Products
Related Knowledges
What is Transformer Vector Groups?
What is Transformer Vector Groups?
Transformer Vector Group DefinitionThe transformer vector group denotes the phase difference between the primary and secondary sides of a transformer, while also defining the arrangement of high-voltage and low-voltage windings in three-phase transformers. Vector groups are determined by the connection configurations of three-phase transformers, which can be categorized into four main groups based on the phase difference between corresponding line voltages of the high-voltage and low-voltage sid
Edwiin
06/02/2025
What is a Pure Resistive AC Circuit?
What is a Pure Resistive AC Circuit?
Pure Resistive AC CircuitA circuit containing only a pure resistanceR(in ohms) in an AC system is defined as a Pure Resistive AC Circuit, devoid of inductance and capacitance. Alternating current and voltage in such a circuit oscillate bidirectionally, generating a sine wave (sinusoidal waveform). In this configuration, power is dissipated by the resistor, with voltage and current in perfect phase—both reaching their peak values simultaneously. As a passive component, the resistor neither
Edwiin
06/02/2025
What is a Pure Capacitor Circuit?
What is a Pure Capacitor Circuit?
Pure Capacitor CircuitA circuit comprising only a pure capacitor with capacitanceC(measured in farads) is termed a Pure Capacitor Circuit. Capacitors store electrical energy within an electric field, a characteristic known ascapacitance(alternatively referred to as a "condenser"). Structurally, a capacitor consists of two conductive plates separated by a dielectric medium—common dielectric materials include glass, paper, mica, and oxide layers. In an ideal AC capacitor circuit, the current
Edwiin
06/02/2025
Resonant Frequency
Resonant Frequency
In a series circuit, the resonant frequency condition occurs when the inductive reactance equals the capacitive reactance. Changing the supply frequency alters the values of XL = 2πfL and XC = 1/2πfC.As the frequency increases, XL rises whileXC falls. Conversely, a decrease in frequency causesXL to drop andXCto rise.To achieve series resonance, the frequency is tuned to fr(pointP in the curve below), whereXL = XC.At series resonance, when XL = XCWhere frdenotes the resonant frequency in he
Edwiin
06/02/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Mesh Current Analysis Method
Mesh Current Analysis Method
The Mesh Current Analysis Method is utilized to analyze and solve electrical networks with multiple sources or circuits comprising numerous meshes (loops) containing voltage or current sources. Also known as the Loop Current Method, this approach involves assuming a distinct current for each loop and determining the polarities of voltage drops across loop elements based on the assumed direction of the loop current.In mesh current analysis, the unknowns are the currents in different meshes, and t
Edwiin
06/02/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放