• MNS type 380V 660V LV withdrawable switchgear
MNS type 380V 660V LV withdrawable switchgear
discuss personally
Model
MNS-660
MNS-380
Basic info
Brand ROCKWILL
Model NO. MNS type 380V 660V LV withdrawable switchgear
Rated insulation voltage 660V
Rated current Horizontal bus bar 630-5000A
Rated current Vertical bus bar 800-2000A
Rated working voltage 380V
Series MNS
Product Detail

Description :

MNS LV withdrawable switchgear (hereinafter referred to as device) is manufactured by standard module through consulting MNS series low voltage switch cabinet of Switzerland ABB Company, and synthetically improved. The device is applicable to the system with AC 50Hz, rated working voltage 660V and below, used as control device for various power generation, transmission, distribution, power transfer and power consumption device.

It is widely used in low voltage distribution system of various mining enterprise, tall building and h otel, municipal construction etc. Besides the general land use, after special disposal, it also can be used for marine petrol drill taken platform and nuclear power station. The device accords with international standard IEC439-1 and national standard GB7251.1.

Main feature :

  • Compact design: Contain more function units with less space. 

  • Strong versatility for structure, flexible assembly. C type bar section of 25mm modulus can meet the demands of various structure and type, protection grade and operating environment. 

  •  Adopt standard module design, can be combined into protection, operation, transfer, control, regulation, measurement, indication etc such standard units. User can choose assembly according to requirement at will. Cabinet structure and drawer unit can be formed with more than 200 components. 

  • Fine security: Adopt high strength antiflaming type engineering plastic pack in large quantity to effectively enhance the protective safety performance. 

  • High technical performance: Main parameters reach the advanced level at home.

Main technical parameters:

image.png

image.png

Conditions for normal operating environment:

  • Ambient air temperature: -5℃ ~+40℃  and the average temperature should not exceed +35℃  in 24h.

  • Air condition: With clean air. Relative humidity should not exceed 50% at +40℃  . Higher relative humidity is allowed at lower temperature. Ex. 90% at +20℃ . But in view of the temperature change, it is possible that moderate dews will produce casually. 

  •  Altitude above sea level should not exceed 2000M. 

  • The device is suitable to the transportation and store with following temperature :-25℃  ~+55℃  , in short time (within 24h) it reaches +70℃  . Under the limiting temperature, device should not suffer damage that can' t recover, and it can works normally under normal conditions.

  • If the above operating conditions not meet user's demand. Consult with manufactory.

  • Technical agreement should be signed additionally if the device is used for marine petrol drill taken platform and nuclear power station.

Interior structure Diagram:

PC cabinet

image.png

Draw-out type MCC cabinet (Single side operation)

image.png

Q:What is withdrawable switchgear?

A:Withdrawable switchgear is a type of electrical switchgear that allows the circuit breaker and other components to be easily withdrawn from the main body of the switchgear for maintenance, repair or replacement without having to disconnect the entire power supply system. It enhances the flexibility and maintainability of the power system.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Restricted.
MNS Type LV withdrawable switchgear
Manual English
Consulting
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!