• 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
discuss personally
Model
ZGS-13/1000
ZGS-13/2000
ZGS-13/2500
ZGS-13/250
Basic info
Brand ROCKWILL
Model NO. ZGS-13 Series Pad Mounted Transformer
Capacity 2500kVA
Series ZGS
Product Detail

Product overview:

The ZGS-13 Series Pad Mounted Transformer delivers a cost-effective, high-reliability, and intelligent solution for urban power distribution. This 250 kVA pad mounted transformer integrates a transformer, switchgear, fuses, tap changers, low-voltage distribution devices, and auxiliary equipment, supporting configurations for energy metering, reactive power compensation, low-voltage shunting, and more.

Designed for 50Hz/60Hz AC systems with a maximum operating voltage of 38.5kV, it suits diverse applications in industrial parks, urban residential areas, commercial centers, high-rise buildings, and other urban infrastructure.

Widely exported to North America, East Asia, Southeast Asia, and the Middle East, the series offers OEM/ODM services to meet customized needs. It complies with international and domestic standards, including ANSI C57, IEEE, DOE, CSA, IEC 60067, GB 1094, GB 17467-2010, GB/T 14048.8.1, and GB 4208.

Product Advantages

Cutting-Edge Technology

  • Fully Enclosed Insulation: Ensures safe, reliable operation with the structure isolating internal components from external hazards.

  • Optimal Performance: Features low loss, noise, and temperature rise, coupled with exceptional overload capacity and sudden short-circuit resistance.

  • Flexible Configuration: Supports both terminal and ring network systems, enabling easy conversion to enhance power supply reliability.

  • Cost-Efficient Operation: Requires minimal maintenance, offers user-friendly operation, and reduces overall equipment costs.

Enclosure Design

  • Premium Materials: Constructed from cold-rolled high-quality hot-dip galvanized steel sheets for corrosion resistance.

  • Precision Manufacturing: Laser CNC cutting, drilling, and bending ensure mm-level processing accuracy.

  • Durable Coating: Surface treated with electrostatic spray paint, guaranteeing 30+ years of anti-aging performance.

  • Core Component: Integrates low-loss oil-immersed transformers manufactured by WONE Electric for stable energy conversion.

Processing & Assembly Standards

  • Skilled Workforce: Assembly technicians undergo at least 6 months of specialized training.

  • Automated Wiring: Secondary circuits are cut by automatic equipment to ensure wiring reliability.

  • Torque Control: Bolts are tightened with power tools to meet precise torque specifications.

  • Busbar Fabrication: Copper busbars are CNC-punched and bent for consistent conductivity.

  • Rigorous Testing: Comprehensive pre-delivery inspections ensure seamless on-site operation.

Company Strengths

  • Certifications: Holds authoritative credentials including ISO, CE, CB, UL, etc.

  • Quality System: Implements a perfect SQA management system to maintain product excellence.

  • Comprehensive Services: Provides quick quotation, electrical design support, and OEM/ODM customization.

  • Logistics Efficiency: Ensures short lead times and global delivery capabilities.

  • After-Sales Support: Offers a full-service warranty system, including factory visits for quality verification.

Product parameters:

Rated Voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 34.5kV, 35kV
Maximum Operating Voltage: 38.5kV

Operating Conditions

Temperature Parameters

  • Maximum daily temperature: 40°C

  • Minimum daily temperature: -25°C

  • Maximum daily temperature difference: 25K

  • Average temperature of hottest month: 30°C

  • Maximum annual average temperature: 20°C

  • Average daily relative humidity: ≤95%

  • Average monthly relative humidity: ≤90%

  • Altitude: ≤1000m

  • Solar Radiation Intensity: 0.1W/cm²

  • Maximum Ice Thickness: 10mm

  • Wind Speed (10m Height, 10min Average): 35m/s

  • Ground Horizontal Acceleration: 2m/s²

  • Installation Environment: Outdoor

  • Pollution Grade: Ⅲ

Ordering Instructions

When placing an order, customers are required to provide the following information to ensure precise customization:

Electrical Diagrams

Main loop scheme di:agram and secondary loop system diagram.

Auxiliary circuit electrical schematic diagram and wiring terminal layout.

Mechanical Drawings:

Equipment layout drawing, combination drawing, and floor plan.

Component Specifications:

Brand, model, specification, and quantity of main electrical components.

Cabling Details:

Incoming and outgoing line configurations and cable specifications.

Surface Finishing:

Equipment surface color (specified by RAL chromatic number).

Special Requirements:

Any additional customizations can be negotiated with WONE Electric for tailored solutions.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!