• 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
discuss personally
Model
ZGS-13/1000
ZGS-13/2000
ZGS-13/2500
ZGS-13/250
Basic info
Brand ROCKWILL
Model NO. ZGS-13 Series Pad Mounted Transformer
Capacity 2000kVA
Series ZGS
Product Detail

Product overview:

The ZGS-13 Series Pad Mounted Transformer delivers a cost-effective, high-reliability, and intelligent solution for urban power distribution. This 250 kVA pad mounted transformer integrates a transformer, switchgear, fuses, tap changers, low-voltage distribution devices, and auxiliary equipment, supporting configurations for energy metering, reactive power compensation, low-voltage shunting, and more.

Designed for 50Hz/60Hz AC systems with a maximum operating voltage of 38.5kV, it suits diverse applications in industrial parks, urban residential areas, commercial centers, high-rise buildings, and other urban infrastructure.

Widely exported to North America, East Asia, Southeast Asia, and the Middle East, the series offers OEM/ODM services to meet customized needs. It complies with international and domestic standards, including ANSI C57, IEEE, DOE, CSA, IEC 60067, GB 1094, GB 17467-2010, GB/T 14048.8.1, and GB 4208.

Product Advantages

Cutting-Edge Technology

  • Fully Enclosed Insulation: Ensures safe, reliable operation with the structure isolating internal components from external hazards.

  • Optimal Performance: Features low loss, noise, and temperature rise, coupled with exceptional overload capacity and sudden short-circuit resistance.

  • Flexible Configuration: Supports both terminal and ring network systems, enabling easy conversion to enhance power supply reliability.

  • Cost-Efficient Operation: Requires minimal maintenance, offers user-friendly operation, and reduces overall equipment costs.

Enclosure Design

  • Premium Materials: Constructed from cold-rolled high-quality hot-dip galvanized steel sheets for corrosion resistance.

  • Precision Manufacturing: Laser CNC cutting, drilling, and bending ensure mm-level processing accuracy.

  • Durable Coating: Surface treated with electrostatic spray paint, guaranteeing 30+ years of anti-aging performance.

  • Core Component: Integrates low-loss oil-immersed transformers manufactured by WONE Electric for stable energy conversion.

Processing & Assembly Standards

  • Skilled Workforce: Assembly technicians undergo at least 6 months of specialized training.

  • Automated Wiring: Secondary circuits are cut by automatic equipment to ensure wiring reliability.

  • Torque Control: Bolts are tightened with power tools to meet precise torque specifications.

  • Busbar Fabrication: Copper busbars are CNC-punched and bent for consistent conductivity.

  • Rigorous Testing: Comprehensive pre-delivery inspections ensure seamless on-site operation.

Company Strengths

  • Certifications: Holds authoritative credentials including ISO, CE, CB, UL, etc.

  • Quality System: Implements a perfect SQA management system to maintain product excellence.

  • Comprehensive Services: Provides quick quotation, electrical design support, and OEM/ODM customization.

  • Logistics Efficiency: Ensures short lead times and global delivery capabilities.

  • After-Sales Support: Offers a full-service warranty system, including factory visits for quality verification.

Product parameters:

Rated Voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 34.5kV, 35kV
Maximum Operating Voltage: 38.5kV

Operating Conditions

Temperature Parameters

  • Maximum daily temperature: 40°C

  • Minimum daily temperature: -25°C

  • Maximum daily temperature difference: 25K

  • Average temperature of hottest month: 30°C

  • Maximum annual average temperature: 20°C

  • Average daily relative humidity: ≤95%

  • Average monthly relative humidity: ≤90%

  • Altitude: ≤1000m

  • Solar Radiation Intensity: 0.1W/cm²

  • Maximum Ice Thickness: 10mm

  • Wind Speed (10m Height, 10min Average): 35m/s

  • Ground Horizontal Acceleration: 2m/s²

  • Installation Environment: Outdoor

  • Pollution Grade: Ⅲ

Ordering Instructions

When placing an order, customers are required to provide the following information to ensure precise customization:

Electrical Diagrams

Main loop scheme di:agram and secondary loop system diagram.

Auxiliary circuit electrical schematic diagram and wiring terminal layout.

Mechanical Drawings:

Equipment layout drawing, combination drawing, and floor plan.

Component Specifications:

Brand, model, specification, and quantity of main electrical components.

Cabling Details:

Incoming and outgoing line configurations and cable specifications.

Surface Finishing:

Equipment surface color (specified by RAL chromatic number).

Special Requirements:

Any additional customizations can be negotiated with WONE Electric for tailored solutions.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the application and improvement directions of current transformers in power systems?
What are the application and improvement directions of current transformers in power systems?
As a front - line power operation and maintenance worker, I deal with current transformers (CTs) daily. Having witnessed the popularization of new photoelectric CTs and tackled numerous faults, I’ve gained practical insights into their application and testing improvements. Below, I’ll share my on - site experience with new CTs in power systems, aiming for a balance between professionalism and practicality.1. Application of New CTs in Power Systems1.1 CTs in Power SystemsMost new CTs
Echo
07/04/2025
What are the troubleshooting methods for current transformers?
What are the troubleshooting methods for current transformers?
As a front - line fault maintenance worker, I deal with current transformers (CTs) daily. A CT’s secondary winding in operation must never open - circuit! Once open - circuited, the secondary current and demagnetizing potential vanish. All primary - side magnetic potential then becomes the iron core’s exciting potential, sharply increasing its magnetic flux density. High voltage on the secondary side will endanger safety anytime.Despite strict power operation regulations, user electr
Felix Spark
07/04/2025
What are the criteria for selection of distribution transformer?
What are the criteria for selection of distribution transformer?
Transformer Selection Criteria: Essential Factors for Optimal PerformanceSelecting the appropriate transformer is critical for ensuring power distribution reliability across industrial, commercial, and residential systems. This process requires meticulous evaluation of load dynamics, environmental constraints, and regulatory standards. Below we outline key selection criteria to guide engineers and designers in making informed decisions.1. Maximum Demand AssessmentThe transformer’s capacity (kVA)
Master Electrician
07/03/2025
What are the causes of current transformer faults and the countermeasures for faults?
What are the causes of current transformer faults and the countermeasures for faults?
As a front - line maintenance technician, I deal with current transformers (CTs) daily. CTs convert high - magnitude primary current to low - magnitude secondary current for substation/line protection and measurement, operating in series long - term. However, they face faults from external (unbalanced loads, wrong wiring, etc.) and internal (insulation defects) issues. These faults, like secondary open - circuits or insulation breakdown, harm measurement accuracy, protection operation, and grid
Felix Spark
07/03/2025
Testing of Optical Current Transformers (OCT)
Testing of Optical Current Transformers (OCT)
With the development of modern economy and science and technology, photoelectric current transformers (PECTs) have fully transitioned from the trial operation stage to practical application. As a front - line testing personnel, I deeply feel their importance in the power system during daily work. I also realize the necessity of conducting in - depth research on their testing systems and calibration methods. This not only promotes the engineering application of PECTs but also enables the accurate
Oliver Watts
07/03/2025
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!