• LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
  • LRP Series switching power supply
LRP Series switching power supply
$13.50
Model
LRS-250-24
LRS-250-12
LRS-200-24
LRS-200-12
LRS-150-24
LRS-150-12
LRS-120-24
LRS-120-12
LRS-100-24
LRS-100-12
LRS-75-24
LRS-75-12
LRS-60-24
LRS-60-12
LRS-50-24
LRS-50-12
LRS-35-24
LRS-35-12
Basic info
Brand Wone Store
Model NO. LRP Series switching power supply
Rated power 150W
Certification CE
Insulation resistance ≥100MΩ(500VDC)
Operating environment -10℃~60℃
Terminal type Threaded type
Wide voltage input range AC100V-260V
rated output of CH1 12V,12.5A
Wide frequency range 47-63Hz
Series LRP Series
Product Detail

30 - 500W Chassis - type Switching Power Supplies without PFC (with an independent housing for easy installation) have a relatively wide power coverage and a relatively sturdy structure, but lack power factor correction. Their application scenarios are concentrated in fields that are cost - sensitive, have lenient energy efficiency standards, and require a certain degree of protection. 

      ●Industrial auxiliary equipment: Such as control power supplies for small conveyor belts, local lighting systems in workshops, power supply modules for non-precision testing instruments, etc. The casing can provide basic dust and moisture protection, and the scenarios where they are used have a high tolerance for power grid harmonics.

      ●Commercial low-cost equipment: Power supplies inside small commercial refrigerators, vending machines, and simple security monitoring host units, etc. These need to be fixedly installed and have requirements for physical protection of the power supply, but do not need to comply with strict energy efficiency regulations.

      ●Regionally characteristic electromechanical products: Small water pumps in some regions, household dehumidifiers (non-energy-saving models), etc. The casing design meets the equipment integration requirements, and there are no mandatory requirements for power factor locally.

      ●Temporary or outdoor equipment: Power supplies for mobile stage lighting, outdoor temporary power supply boxes (for short-term use), etc. The casing can improve durability, and short-term use has limited impact on the power grid.

It should be noted that their application is limited in regions with strict energy efficiency regulations (such as the EU and North America), and they are not suitable for sharing the power grid with precision electronic equipment to avoid abnormalities caused by harmonic interference.

 

Features:

Wattage:35W-400W

Universal AC Input

Non-PFC, most economical models

Ultra compact and 1U low profile

No load power consumption: 0.2W~0.75W

Operating altitude up to 5000 meters

LED indicator for power on

100% full load burn-in test

2 years warranty

 

selection reference

 

If you need to know about or order switching power supplies of other specifications, Please check the model selection manual.↓↓↓ 

Or you are welcome to contact us.→→→

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Switchgear parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!