• JW10 Series HV Grounding Switch
JW10 Series HV Grounding Switch
discuss personally
Model
JW10-550
JW10-420
JW10-363
JW10-252
JW10-170
JW10-145
JW10-126
JW10-72.5
JW10-40.5
Basic info
Brand Wone
Model NO. JW10 Series Grounding Switch
Rated voltage 550kV
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series JW10 Series
Product Detail

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
With the increasing complexity of power system operation environment and the deepening of power system reform, traditional power grids are accelerating the transformation to smart grids. The goal of equipment condition-based maintenance is achieved through real-time perception of equipment status by new sensors, reliable communication via modern network technology, and effective monitoring by background expert systems.I. Analysis of Condition-based Maintenance StrategyCondition-based Maintenance
Oliver Watts
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放