Model
JW10-550
JW10-420
JW10-363
JW10-252
JW10-170
JW10-145
JW10-126
JW10-72.5
JW10-40.5
Basic info
Brand Wone
Model NO. JW10 Series Grounding Switch
Rated voltage 126kV
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series JW10 Series
Product Detail

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放