Model
JW10-550
JW10-420
JW10-363
JW10-252
JW10-170
JW10-145
JW10-126
JW10-72.5
JW10-40.5
Basic info
Brand Wone
Model NO. JW10 Series Grounding Switch
Rated voltage 363kV
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series JW10 Series
Product Detail

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Research on Power Quality Issues and Control Technologies at Distribution Transformer Terminals in PV Charging Stations
Research on Power Quality Issues and Control Technologies at Distribution Transformer Terminals in PV Charging Stations
1. IntroductionAs a frontline designer of photovoltaic charging station distribution systems, I deeply engage in power quality control technology research. Amid energy transition, photovoltaic charging stations grow in importance, yet large - scale PV integration brings power quality challenges. The distribution transformer end, a key node, urgently needs solutions. Despite existing research, gaps remain in control tech considering PV characteristics and complex conditions. This paper focuses on
Dyson
06/24/2025
Fault Diagnosis Analysis for Pad-Mounted Transformers in PV Power Plants
Fault Diagnosis Analysis for Pad-Mounted Transformers in PV Power Plants
As a front - line fault diagnosis and detection worker, I am well aware that with the expansion of the scale of photovoltaic power stations, the faults of box - type transformers, as one of the key equipment, have a profound impact on the stable operation of the system. This paper focuses on using advanced artificial intelligence algorithms and integrating data analysis technology to improve the accuracy and efficiency of fault diagnosis of box - type transformers, and to build a solid technical
Oliver Watts
06/24/2025
What is the operation mode of the step-up transformer in photovoltaic power generation?
What is the operation mode of the step-up transformer in photovoltaic power generation?
1 Overview of Photovoltaic Power Generation ProcessIn my daily work as a frontline operation and maintenance technician, the photovoltaic power generation process I encounter involves connecting individual solar panels into photovoltaic modules, which are then paralleled through combiner boxes to form a photovoltaic array. Solar energy is converted into direct current (DC) by the photovoltaic array, then transformed into three-phase alternating current (AC) via a three-phase inverter (DC-AC). Su
Echo
06/24/2025
Field Testing Procedures for Electric Vehicle Charging Piles
Field Testing Procedures for Electric Vehicle Charging Piles
As a technician deeply involved in charging pile testing on the frontline, my daily work makes one thing crystal clear: as people’s living standards rise, the demand for vehicles surges. Coupled with the growing popularity of environmental protection concepts, the electric vehicle (EV) industry is booming. Charging piles, as the “lifeline” of electric vehicles, directly determine whether EVs can operate stably and safely. Put simply, our job in testing is to “diagnose&rdq
Oliver Watts
06/24/2025
Design and Application of Smart EV Charging Piles
Design and Application of Smart EV Charging Piles
As a charging pile designer deeply involved in industry projects, I've witnessed firsthand how electric vehicles (EVs) have become a pivotal force in China's new energy landscape. Decades of advancements in electronics have laid a solid foundation for EV development. The integration of V2G, energy storage technologies, and high-performance batteries not only facilitates battery swapping services but also drives the convergence of photovoltaics, energy storage, and intelligent charging systems&md
Echo
06/24/2025
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
Electric Vehicle Charging Pile Testing Technologies and Failure Analysis
1. Detection Technology for Electric Vehicle Charging PilesEV charging piles are primarily divided into two categories:DC charging pilesandAC charging piles. Let's start with DC charging piles: they communicate with the EV's battery management system (BMS) and directly charge the power battery through the DC charging interface. AC charging piles, on the other hand, rely on the EV's AC charging interface and use the vehicle-mounted charger to complete the charging process. These two types of char
Oliver Watts
06/23/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!