• JW10 Series HV Grounding Switch
JW10 Series HV Grounding Switch
discuss personally
Model
JW10-550
JW10-420
JW10-363
JW10-252
JW10-170
JW10-145
JW10-126
JW10-72.5
JW10-40.5
Basic info
Brand Wone
Model NO. JW10 Series Grounding Switch
Rated voltage 252kV
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 50kA
Series JW10 Series
Product Detail

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What aspects does the inspection of industrial and commercial energy storage cover?
What aspects does the inspection of industrial and commercial energy storage cover?
As a frontline tester, I work with industrial and commercial energy storage systems daily. I know firsthand how critical their stable operation is for energy efficiency and business profitability. While installed capacity grows rapidly, equipment failures increasingly threaten ROI—over 57% of energy storage plants reported unplanned outages in 2023, with 80% stemming from equipment defects, system anomalies, or poor integration. Below, I share practical testing insights for the five core s
Oliver Watts
06/21/2025
Commercial and Industrial Energy Storage Systems
Commercial and Industrial Energy Storage Systems
I. Core Value Proposition✅ Energy Cost Optimization: Reduce electricity expenses by 30%-50% through peak-valley arbitrage (EU peak/off-peak spreads up to €0.25/kWh) ✅ Power Reliability: Seamless backup power switching (<20ms response) for critical operations ✅ Renewables Integration: Increase solar self-consumption to >90%, minimizing curtailment losses ✅ Carbon Reduction: Achieve ~500 tons CO₂e annual reduction (1MW/2MWh system reference) II. Key Application Scenarios & Solutions
RW Energy
06/21/2025
AI-Enhanced Grid Frequency Regulation System Design for Commercial & Industrial Energy Storage Systems
AI-Enhanced Grid Frequency Regulation System Design for Commercial & Industrial Energy Storage Systems
As renewable energy penetration rises in modern power systems and load variability grows increasingly complex, instability issues—especially frequency fluctuations—have become more prominent. Intelligent commercial and industrial energy storage systems address this challenge by leveraging AI to boost grid - frequency regulation efficiency and accuracy. They enable real - time frequency monitoring, millisecond - level charge/discharge responses, intelligent scheduling with continuous
Dyson
06/21/2025
What are the maintenance and fault prevention measures for industrial and commercial energy storage systems?
What are the maintenance and fault prevention measures for industrial and commercial energy storage systems?
As a front-line practitioner in commercial and industrial energy storage, I understand deeply that scientific prevention and maintenance strategies are crucial for long-term system stability. Here’s my professional summary based on years of field experience:1. Core Strategies for Fault Prevention and MaintenanceBattery SystemIn daily operations, I've found precise parameter control essential. Maintain battery temperature at 25±2℃, triggering alarms when deviating by ±15℃. Lim
Felix Spark
06/21/2025
What are the common faults that occur during the operation of equipment related to industrial and commercial energy storage?
What are the common faults that occur during the operation of equipment related to industrial and commercial energy storage?
As an important part of the new power system, the stable operation of commercial and industrial energy storage systems is directly related to energy utilization efficiency and enterprise economic benefits. With the rapid growth of the installed capacity of commercial and industrial energy storage, equipment failure rate has become a key factor affecting investment returns. According to data from the China Electricity Council, in 2023, the proportion of unplanned outages of energy storage power s
Felix Spark
06/21/2025
Operational Analysis of Distributed Energy Storage Systems for Commercial & Industrial Behind-the-Meter Applications
Operational Analysis of Distributed Energy Storage Systems for Commercial & Industrial Behind-the-Meter Applications
Energy storage technology, a focal point in new energy, stores electricity for grid peak/valley supply adjustment. Distributed energy storage in commercial/industrial contexts cuts costs via peak - shaving, boosts grid stability, and mitigates peak - valley imbalances. This paper explores its application for commercial/industrial users from scenarios and feasibility.1 Application Scenario Analysis1.1 Demand AnalysisElectricity costs dominate commercial/industrial energy expenses, especially for
Echo
06/21/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!