• (H)RW12 Outdoor HV AC Drop Fuse
(H)RW12 Outdoor HV AC Drop Fuse
discuss personally
Model
(H)RW12-38(F)/200-8
(H)RW12-38(F)/100-6.3
(H)RW12-36(F)/200-8
(H)RW12-36(F)/100-6.3
(H)RW12-33(F)/200-8
(H)RW12-33(F)/100-6.3
(H)RW12-24(F)/200-10
(H)RW12-24(F)/100-8
(H)RW12-17(F)/200-12
(H)RW12-17(F)/100-10
(H)RW12-12(F)/200-12
(H)RW12-12(F)/100-10
Basic info
Brand Wone
Model NO. (H)RW12 Outdoor HV AC Drop Fuse
Rated voltage 38kV
Rated normal current 200A
Rated frequency 50/60Hz
Rated short circuit breaking current 8kA
Series (H)RW12
Product Detail

Description:

   (H)RW12-12(F) outdoor high voltage AC drop fuse (hereinafter referred to as "fuse"), suitable for outdoor overhead power distribution system with rated frequency 50Hz and rated voltage 10kV, as overload or short circuit fault of power system Protective element of a circuit or electrical device. When the fuse is in normal operation, it is connected in series in the power line, the fuse is in tension, and the movable joint is locked. When the line fails, the fault current causes the fuse to blow, the movable joint is released, the fuse is quickly dropped, the circuit is cut off, and the protection of the line and equipment is safe. The load type fuse adds a spring contact and an arc extinguishing cover on the basis of the common type, and is used for dividing the load current in the power system. The fuse meets the technical standards of GB/T 15166.3-2008 "High Voltage AC Fuse Part 3: Jet Fuse", DL/T 640-1997 "Outdoor AC High Voltage Drop Fuse and Fuse Parts Ordering Technical Conditions".

Parameter:

Parts illustration:

Parts illustration.png

Technical Information:

Technical Information_修复后.png

Overall and installation dimensions:

Overall and installation dimensions_修复后.png

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What is Transformer Vector Groups?
What is Transformer Vector Groups?
Transformer Vector Group DefinitionThe transformer vector group denotes the phase difference between the primary and secondary sides of a transformer, while also defining the arrangement of high-voltage and low-voltage windings in three-phase transformers. Vector groups are determined by the connection configurations of three-phase transformers, which can be categorized into four main groups based on the phase difference between corresponding line voltages of the high-voltage and low-voltage sid
Edwiin
06/02/2025
What is a Pure Resistive AC Circuit?
What is a Pure Resistive AC Circuit?
Pure Resistive AC CircuitA circuit containing only a pure resistanceR(in ohms) in an AC system is defined as a Pure Resistive AC Circuit, devoid of inductance and capacitance. Alternating current and voltage in such a circuit oscillate bidirectionally, generating a sine wave (sinusoidal waveform). In this configuration, power is dissipated by the resistor, with voltage and current in perfect phase—both reaching their peak values simultaneously. As a passive component, the resistor neither
Edwiin
06/02/2025
What is a Pure Capacitor Circuit?
What is a Pure Capacitor Circuit?
Pure Capacitor CircuitA circuit comprising only a pure capacitor with capacitanceC(measured in farads) is termed a Pure Capacitor Circuit. Capacitors store electrical energy within an electric field, a characteristic known ascapacitance(alternatively referred to as a "condenser"). Structurally, a capacitor consists of two conductive plates separated by a dielectric medium—common dielectric materials include glass, paper, mica, and oxide layers. In an ideal AC capacitor circuit, the current
Edwiin
06/02/2025
Resonant Frequency
Resonant Frequency
In a series circuit, the resonant frequency condition occurs when the inductive reactance equals the capacitive reactance. Changing the supply frequency alters the values of XL = 2πfL and XC = 1/2πfC.As the frequency increases, XL rises whileXC falls. Conversely, a decrease in frequency causesXL to drop andXCto rise.To achieve series resonance, the frequency is tuned to fr(pointP in the curve below), whereXL = XC.At series resonance, when XL = XCWhere frdenotes the resonant frequency in he
Edwiin
06/02/2025
Current Division and Voltage Division Rule
Current Division and Voltage Division Rule
Current Division RuleA parallel circuit functions as a current divider, where the incoming current splits among all branches while the voltage across each branch remains constant. The Current Division Rule is used to determine the current through circuit impedances, as illustrated by the circuit below:The currentI splits intoI1 andI2 across two parallel branches with resistancesR1 andR2, whereVdenotes the voltage drop across both resistances. As is known,Then the equation of the current is writt
Edwiin
06/02/2025
Mesh Current Analysis Method
Mesh Current Analysis Method
The Mesh Current Analysis Method is utilized to analyze and solve electrical networks with multiple sources or circuits comprising numerous meshes (loops) containing voltage or current sources. Also known as the Loop Current Method, this approach involves assuming a distinct current for each loop and determining the polarities of voltage drops across loop elements based on the assumed direction of the loop current.In mesh current analysis, the unknowns are the currents in different meshes, and t
Edwiin
06/02/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放