• Solar Power Equipment Box-type Transformer(Prefabricated Substation)
Solar Power Equipment Box-type Transformer(Prefabricated Substation)
discuss personally
Model
SHN-1600-2
Basic info
Brand Vziman
Model NO. Solar Power Equipment Box-type Transformer
Rated voltage 33kV
Capacity 500kVA-1600kVA
Series Compact Substation
Product Detail

Product overview: 

  • A Solar Power Equipment Box-type Transformer that integrates 0.27kV 0.315kV 0.69kv voltage of grid-connected photovoltaic inverter into power grid output energy through a boost transformer.

  •  High-voltage switchgear, transformer body and protective fuse are centrally placed in the oil tank. High-voltage/low-voltage pre-installed substation is set up together with low-voltage switchgear and corresponding auxiliary equipment.

  •  Mainly used for small and medium-sized solar power generation.

  •  Execution standard: IEC61850 series, GB/T17467, etc.

Product advantages:

Leading technology:

  •  Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  •  Compact structure, small footprint, easy installation.

  •  Fully enclosed, fully insulated structure, safe and reliable operation.

  •  Easy to operate, maintenance-free, low equipment cost.

Enclosure:

  •  Adopt cold rolled high quality hot dip galvanized sheet.

  •  The surface is treated by electrostatic spray, and the paint can not be taken off for 50 years.

  •  Laser numerical control equipment cutting, drilling, bending, to ensure the processing accuracy.

  •  Product structure is divided into three parts: high voltage chamber, low voltage chamber and transformer.

  •  The cabinet is mainly pre-installed with: lightning arrester, load switch, transformer tap switch, protection fuse, oil level thermometer, oil level gauge, pressure relief valve, amount of oil discharge valve and other accessories.

  •  The low-voltage side is equipped with main circuit breaker, overvoltage protector, and can be designed and installed in complete sets of automatic measurement and intelligent control system.

  •  The transformer is a low loss oil-immersed transformer produced by WONE You Electric.

Functional units:

  •  Fully sealed structure, using the transformer insulating oil as the insulating medium and heat dissipation medium, overall has the advantages of compact structure, good heat dissipation performance.

  •  The high-voltage indoor door should be equipped with electromagnetic lock and live display. When the high-voltage side is live, the high-voltage chamber door cannot be opened.

  • The external door of the box transformer should be equipped with mechanical lock to meet the five requirements of high-pressure products and ensure personal safety.

 Components:

  •  Choose high-quality brand components such as Chint, Shanghai People Electric, Changshu Electric, etc.

  •  Schneider, ABB high-quality partners.

Supplementary material:

  •  High quality tin - plated busbar copper bar, with insulation sleeve.

  •  Hanhe cable is selected for secondary wiring.

 Processing and assembly:

  • Assembly workers have been trained for at least 6 months.

  • Secondary wiring is fully automatic equipment cutting to ensure reliable wiring.

  • Use power tools to ensure proper torque for bolting reinforcement.

  • The copper wire bus is NC punched and bent.

  • All kinds of experimental tests before leaving the factory to ensure normal operation.

Product parameters:

  • Voltage:0.69kV/33kV  0.69kV/11kV.

Conditions of use:

  •  Altitude: ≦2000m.

  • Ambient temperature range: -45℃ -- +45℃.

  • Outdoor wind speed: ≤35m/s.

  • Relative humidity: daily mean ≤95%, monthly mean ≤90%.

  • Installation location: Install in the place without fire, explosion risk, serious pollution, chemical corrosion and violent vibration.

  • If the above normal operating conditions are exceeded, customers can contact our company for customized solutions.

  • The above is suitable for 50/60Hz photovoltaic power generation system, the rated capacity of the transformer is 500~ 1600kVA.

Ordering instructions:

When ordering, the customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  •  Equipment layout drawing, combination drawing, floor plan drawing.

  • Brand, model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Device surface color.

  • Other special requirements can be negotiated with the manufacturer.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!