• GZDW Type DC power supply cabinet
GZDW Type DC power supply cabinet
discuss personally
Model
GZDW-220-48
GZDW-220-110
GZDW-220-220
GZDW-380-220
Basic info
Brand Wone
Model NO. GZDW Type DC power supply cabinet
Rated frequency 50Hz ± 5%
AC input voltage AC220V ± 10%
DC output voltage DC48V
Series GZDW
Product Detail

Description :

I produced GZDW series DC power screen widely used in the power system large,  medium and small power stations and substations and other electrical equipment,  secondary circuit protection devices DC power system, as a control, signaling,  communications, protection and DC emergency lighting, motor starting and power units  and other power equipment can also be used for post and telecommunications and other  industries to meet the needs of power engineering, but also can be used as a DC voltage,  constant current power supply, and other DC operating power. Our company is strong in technology, product performance and stability, has won  the trust of customers, products sold throughout the country and abroad, is the Ministry  of Power Industry sentinel GZDW series DC power supply cabinet (hereinafter referred  to as: DC cabinet) production enterprises. Products in strict accordance with  international and national quality assurance production, product type testing by the  Ministry and experts management system, in line with JB / T 5777.4-2000 "power  system DC power supply General technical conditions and safety requirements" and DL  / T459-2000 "Power system DC power supply cabinet order technical conditions  "requirement. This product uses high-frequency switching power supply module or  phase-controlled rectifier device as charging float charging devices. GZDW with  technical indicators advanced, low maintenance, high efficiency, small size and other  characteristics of the battery charge, floating charge and DC power intelligent  management of working conditions, protection of battery life. Equipped computer  controller (PLC controller or microcontroller) of the product also has a remote function,  improve the reliability and automation level of the DC system.

Technical feature:

  • Efficient power conversion technology.

  • Intelligent management function.

  • Compact structural layout.

  • High-reliability design.

  • Good electromagnetic compatibility.

  • Flexible configuration and expandability.

Main technical parameters:

GZDW Type DC power supply cabinet.png

The use of environmental conditions:

GZDW Type DC power supply cabinet.png

Should you ground a DC power supply?

A:Yes, in many cases, it is necessary to ground a DC power supply. Grounding helps to improve safety by preventing electric shock in case of insulation failure. It also helps to reduce electromagnetic interference and stabilize the electrical potential of the power supply, which is beneficial for the proper operation of electronic devices. However, there are some specific low - voltage and isolated DC power supplies that may not require grounding depending on the application and safety regulations.

image.png

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!