• HY5(10)W Series arresters
HY5(10)W Series arresters
discuss personally
Model
HY10W-120/325
HY10W-60/170
HY10W-45/127.5
HY10W-42/119
HY10W-36/102
HY10W-33/93.5
HY10W-30/85
HY10W-27/76.5
HY10W-24/68
HY10W-21/59.5
HY10W-18/51
HY10W-15/42.5
HY10W-12/34
HY10W-9/25.5
HY10W-6/17
HY10W-3/8.5
HY5W-36/102
HY5W-33/93.5
HY5W-30/85
HY5W-27/76.5
HY5W-24/68
HY5W-18/51
HY5W-15/42.5
HY5W-12/34
HY5W-9/25.5
HY5W-6/17
HY5W-3/8.5
Basic info
Brand Wone
Model NO. HY5(10)W Series arresters
Rated voltage 36kV
Discharge current 5kA
Lightning impulse residual voltage 102kV
Series HY5(10)W
Product Detail

Product introduction:

  •  Polymer-Housed Arresters 9-24kV/5kA, 15-60kV/10kA (KEMA TESTED).

  • Polymer-Housed Arresters up to 220kV.

  •  Porcelain-Housed Arresters up to 500kV.

  • Tested according to IEC 60099-4.

  • Certified to ISO 9001 and ISO 14001.

Technical Information

微信截图_20241205162542.png

微信截图_20241205162553.png

微信截图_20241205162603.png

微信截图_20241205162617.png

微信截图_20241205162627.png

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Phasor Method for Solving Parallel Circuits
Phasor Method for Solving Parallel Circuits
When dealing with parallel circuits, multiple branches are connected in parallel. Each branch contains components such as resistors, inductors, and capacitors, forming a series circuit within that branch. Each branch is first analyzed separately as a series circuit, and then the effects of all branches are combined.In circuit calculations, both the magnitude and phase angle of current and voltage are taken into account. When solving the circuit, the magnitudes and phase angles of voltages and cu
Edwiin
05/30/2025
Permanent Magnet Moving Coil or PMMC Instrument
Permanent Magnet Moving Coil or PMMC Instrument
DefinitionInstruments that utilize a permanent magnet to generate a stationary magnetic field within which a coil moves are known as Permanent Magnet Moving Coil (PMMC) instruments. They operate on the principle that torque is exerted on a moving coil situated in the magnetic field of a permanent magnet. PMMC instruments provide accurate results for direct current (DC) measurements.Construction of PMMC InstrumentThe moving coil and the permanent magnet are the key components of a PMMC instrument
Edwiin
05/30/2025
Difference Between Porcelain and Glass Insulators
Difference Between Porcelain and Glass Insulators
Key Differences Between Glass and Porcelain InsulatorsBoth porcelain and glass insulators are widely applied in power transmission and distribution to insulate overhead line conductors from supporting towers and poles. With extended service lives and suitability for high voltage ratings, their unique characteristics and properties define their distinct application scenarios.Porcelain InsulatorsPorcelain, a ceramic material, is valued for its absence of internal defects such as voids, cracks, or
Edwiin
05/30/2025
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is Static VAR Compensator (SVC)? Circuit & Operation in PF Correction
What is a Static VAR Compensator (SVC)?A Static VAR Compensator (SVC), also termed a Static Reactive Compensator, is a critical device for enhancing the power factor in electrical power systems. As a type of static reactive power compensation equipment, it injects or absorbs reactive power to maintain optimal voltage levels, ensuring stable grid operation.An integral part of the Flexible AC Transmission System (FACTS), an SVC comprises a bank of capacitors and reactors controlled by power electr
Edwiin
05/30/2025
Comparison Between Overhead & Underground Transmission Systems
Comparison Between Overhead & Underground Transmission Systems
Key Differences and Comparison Between Underground and Overhead Power Transmission & DistributionPublic SafetyIn terms of public safety, underground systems outperform overhead transmission systems. With all transmission and distribution components buried, underground setups minimize risks from obstacles and external interference. Additionally, they are less susceptible to environmental factors like wind, storms, and heavy rain, making them inherently more secure.Initial CostUnderground syst
Edwiin
05/30/2025
What is the Difference Between Shunt Reactor and Shunt Capacitor?
What is the Difference Between Shunt Reactor and Shunt Capacitor?
In an electrical power system, various devices are utilized to enhance power factor and operational efficiency. Shunt capacitors and shunt reactors represent two distinct components designed to optimize the performance of electrical grids. This article explores their key differences, beginning with an overview of their fundamental principles.Shunt CapacitorsA shunt capacitor refers to a single capacitor or a group of capacitors (termed a capacitor bank) connected in parallel to the power system.
Edwiin
05/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放