• HY5(10)W Series arresters
HY5(10)W Series arresters
discuss personally
Model
HY10W-120/325
HY10W-60/170
HY10W-45/127.5
HY10W-42/119
HY10W-36/102
HY10W-33/93.5
HY10W-30/85
HY10W-27/76.5
HY10W-24/68
HY10W-21/59.5
HY10W-18/51
HY10W-15/42.5
HY10W-12/34
HY10W-9/25.5
HY10W-6/17
HY10W-3/8.5
HY5W-36/102
HY5W-33/93.5
HY5W-30/85
HY5W-27/76.5
HY5W-24/68
HY5W-18/51
HY5W-15/42.5
HY5W-12/34
HY5W-9/25.5
HY5W-6/17
HY5W-3/8.5
Basic info
Brand Wone
Model NO. HY5(10)W Series arresters
Rated voltage 60kV
Discharge current 10kA
Lightning impulse residual voltage 170kV
Series HY5(10)W
Product Detail

Product introduction:

  •  Polymer-Housed Arresters 9-24kV/5kA, 15-60kV/10kA (KEMA TESTED).

  • Polymer-Housed Arresters up to 220kV.

  •  Porcelain-Housed Arresters up to 500kV.

  • Tested according to IEC 60099-4.

  • Certified to ISO 9001 and ISO 14001.

Technical Information

微信截图_20241205162542.png

微信截图_20241205162553.png

微信截图_20241205162603.png

微信截图_20241205162617.png

微信截图_20241205162627.png

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!