• DS4A  12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
discuss personally
Model
DS4A-170/2000-40
DS4A-145D/4000-50
DS4A-145D/3150-50
DS4A-145D/2500-40
DS4A-145D/2000-40
DS4A-145D/1600-40
DS4A-126D/4000-50
DS4A-126D/3150-50
DS4A-126D/2500-40
DS4A-126D/2000-40
DS4A-126D/1600-40
DS4A-72.5D/4000-50
DS4A-72.5D/3150-50
DS4A-72.5D/2500-40
DS4A-72.5D/2000-40
DS4A-72.5D/1600-40
DS4A-72.5D/1250-40
DS4A-40.5D/4000-50
DS4A-40.5D/3150-40
DS4A-40.5D/2500-40
DS4A-40.5D/2000-31.5
DS4A-40.5D/1250-31.5
DS4A-24D/2000-31.5
DS4A-24D/1250-31.5
DS4A-24D/630-31.5
DS4A-12D/2000-31.5
DS4A-12D/1250-31.5
DS4A-12D/630-31.5
Basic info
Brand ROCKWILL
Model NO. DS4A 12kV 24kV 40.5kV 72.5kV 126kV 145kV 170kV High voltage disconnect switch
Rated voltage 170kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 104kA
Rated short-time withstand current 40kA
Series DS4A
Product Detail

Product introduction:

DS4A-12/126/145/170D(W) Switch Disconnector are kinds of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It’s used for breaking or connecting HV lines under no loads so that the power lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker.

This product has two insulators with horizontal center breaks. itis openable in the middle and accessible to the grounding switch on one side or two sides. The Switch Disconnector adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage. The earthing switch adopts CS14G manual operating mechanism to realize tri-pole linkage.

In August 2005, this product passed the improvement technology review by State Grid Corporation (Jiangsu provincial branch).

DS4A Switch Disconnector comprises three single poles and operating mechanism. Each pole comprises a base, post insulators and conductive parts. Removable insulating posts are mounted at both sides of a long base, The conducive switch blade's contact arms are respectively fixed at the tops of the insulating posts. When the insulating post at one end of the actuator revolves to drive, with the help of the crossover lever, the reverse rotation of the insulating post at the other end by 90", the conductive switch blade will rotate on the horizontal surface to realize the starting and closing of the isolating switch. A horizontal insulating open break will appear at the opening moment.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight, large radiation area and corruption-resistance.
  • Adopt particular copper alloy to develop the self-contained contact, The contact point is tightened by the elastic force of the contact itself. The contact spring is eliminated to avoid possible drop of the contact in gripping force due to the spring's corrosion and shunting, heating and annealing, possible increment in contact resistance, and possible vicious cycle of the growing heat of the contact. The contact is made of curved copper plate, forming a large connection area with he conductive arm. In the opening and closing processes, there isa short trip of friction between the contact and the finger and he required operating force is small. The conductive part has been acknowledged by the Chinese competent authority as a new and practical patent.(Patent No.. Z103 2 20022.6)
  • The rotating parts of the disconnect switch are designed to be free of any maintenance. The rotating base is designed into a seal structure which denies the access of moisture, dust and harmful gases so that No.2 low-temperature lubricating cream within the bearing will not run off or harden, Within the bearing base are thrust ball bearing and radial ball bearing, both of which will share the gravity and horizontal component of the Switch Disconnector so that the operating torque will not increase after the long-term operation of the disconnect switch.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

GW4A-parameters.png

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods ordering time;

The disconnect switch offers several options of grounding (no, left. right. both left and right). Unless otherwise specified, the goods supplied will be considered as proving the option of right grounding;

Notes:

  • The methods of Judging left and right grounding: hold out both arms and keep the arms In the same direction as the Switch Disconnector is open的The earthing switch will be considered as left grounding if on the left hand side, and right grounding if on the right hand side;
  • The actuator's model and name, voltage and the number of contacts for auxiliary switch;
  • Specify the type of power and voltage degree for the electromagnetic lock of the actuator.

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren
James
07/07/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!