• Expulsion fuse cutout
  • Expulsion fuse cutout
Expulsion fuse cutout
discuss personally
Model
HV-24/12
HV-15/12
HV-24/12
Basic info
Brand Wone
Model NO. Expulsion fuse cutout
Rated voltage 38kV
Rated normal current 100/200A
Rated interrupting current 8kA
Series Expulsion fuse
Product Detail

Product features:

High performance of weather aging resistance:

  • For porelain insulator, the porcelain body connects with hardware fitting by cement pouring, we use the (por-rok)ANCHORING cement manufactured by CGM INC from USA. This kind of cement has rapid solidification, high mechanical strength, low expansion coefficient and superior weather resistance.

  • For polymer insulator, the hardware fitting crimped onto fiberglass rod, material of housing and sheds manufacture of high-temperature Vulcanized Silicone Rubber, and the insulator moulded by one piece injection molding. It has good sealing performance and good performance of tracking and erosion resistance.

  • All ferrous parts processed by hot dip galvanized, its zinc coating more than 86u, it has good corrosion resistance.


Design feature of single vent:

  • Our fuse cutout adopts the design feature of single vent, exhaust downwards and outwards when fuse cutout interrput. Prevent the intrusion of rainwater, avoid damage to the upper line by free gas, and this design can improve the interrput capacity.

  • It adopts Arc-shortening copper rod to improve the interrput capacity when short circuit fault.

Excellent conductivity:

  • All copper casting part adopts bronze/brass, it has excellent mechanical strength and excellent conductivity.

  • All contact parts be silver-plated, it adopts convex design on the contact surface, this design can reduce the contact resistance and ensure excellent conductivity.

  • The high-strength memory cooper alloy sheets can ensure contact with lower contact smoothly and without any affecting when fuse drop out.


Reliable load breaking capacity:

  • For Loadbreak type fuse cutout, its arc chamber made of special reinforced nylon material. It has good mechanical strength, anti-aging and flame retardant, suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.

Relevant international executive standards:

  • All fuse cutouts we manufacture and test according to the latest international standard IEC 60282-2:2008 & IEEE Std 037.41-2008 & IEEEStd 037.42-2009.

Product categories:

企业微信截图_173389368371.png

企业微信截图_17338939118484.png

Technical parameter:

企业微信截图_17338941496775.png

企业微信截图_1733894339996 (1).png

企业微信截图_17338945324685.png

企业微信截图_17338946944917.png

Warm tips:

When order.please indicate the detailed information as below listed:

  • Rated voltage and rated current .

  • Minimum creepage distance.

  • The material of insulator.

  • Please indicate whether arc-shortening rod should be fitted with fuse cutout.

  • Please indicate the type of mounting bracket.

How does a expulsion fuse  work?

Normal Operating State:

  • During normal operation, the expulsion fuse allows the normal operating current to pass through. The fusible element conducts current normally, behaving like a regular conductor, without hindering the operation of the power system.

Fault Operating State:

  • When an overload or short-circuit fault occurs in the circuit, causing the current to exceed the rated current of the fuse, the fusible element heats up and melts, generating an arc. The high temperature of the arc causes the gas-producing material inside the fuse to decompose, generating a large amount of high-pressure gas. These gases are expelled at high speed, stretching, cooling, and ultimately extinguishing the arc, thereby interrupting the fault current and protecting the lines and connected electrical equipment.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o