• Expulsion fuse cutout
  • Expulsion fuse cutout
Expulsion fuse cutout
discuss personally
Model
HV-24/12
HV-15/12
HV-24/12
Basic info
Brand Wone
Model NO. Expulsion fuse cutout
Rated voltage 38kV
Rated normal current 100/200A
Rated interrupting current 8kA
Series Expulsion fuse
Product Detail

Product features:

High performance of weather aging resistance:

  • For porelain insulator, the porcelain body connects with hardware fitting by cement pouring, we use the (por-rok)ANCHORING cement manufactured by CGM INC from USA. This kind of cement has rapid solidification, high mechanical strength, low expansion coefficient and superior weather resistance.

  • For polymer insulator, the hardware fitting crimped onto fiberglass rod, material of housing and sheds manufacture of high-temperature Vulcanized Silicone Rubber, and the insulator moulded by one piece injection molding. It has good sealing performance and good performance of tracking and erosion resistance.

  • All ferrous parts processed by hot dip galvanized, its zinc coating more than 86u, it has good corrosion resistance.


Design feature of single vent:

  • Our fuse cutout adopts the design feature of single vent, exhaust downwards and outwards when fuse cutout interrput. Prevent the intrusion of rainwater, avoid damage to the upper line by free gas, and this design can improve the interrput capacity.

  • It adopts Arc-shortening copper rod to improve the interrput capacity when short circuit fault.

Excellent conductivity:

  • All copper casting part adopts bronze/brass, it has excellent mechanical strength and excellent conductivity.

  • All contact parts be silver-plated, it adopts convex design on the contact surface, this design can reduce the contact resistance and ensure excellent conductivity.

  • The high-strength memory cooper alloy sheets can ensure contact with lower contact smoothly and without any affecting when fuse drop out.


Reliable load breaking capacity:

  • For Loadbreak type fuse cutout, its arc chamber made of special reinforced nylon material. It has good mechanical strength, anti-aging and flame retardant, suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.

Relevant international executive standards:

  • All fuse cutouts we manufacture and test according to the latest international standard IEC 60282-2:2008 & IEEE Std 037.41-2008 & IEEEStd 037.42-2009.

Product categories:

企业微信截图_173389368371.png

企业微信截图_17338939118484.png

Technical parameter:

企业微信截图_17338941496775.png

企业微信截图_1733894339996 (1).png

企业微信截图_17338945324685.png

企业微信截图_17338946944917.png

Warm tips:

When order.please indicate the detailed information as below listed:

  • Rated voltage and rated current .

  • Minimum creepage distance.

  • The material of insulator.

  • Please indicate whether arc-shortening rod should be fitted with fuse cutout.

  • Please indicate the type of mounting bracket.

How does a expulsion fuse  work?

Normal Operating State:

  • During normal operation, the expulsion fuse allows the normal operating current to pass through. The fusible element conducts current normally, behaving like a regular conductor, without hindering the operation of the power system.

Fault Operating State:

  • When an overload or short-circuit fault occurs in the circuit, causing the current to exceed the rated current of the fuse, the fusible element heats up and melts, generating an arc. The high temperature of the arc causes the gas-producing material inside the fuse to decompose, generating a large amount of high-pressure gas. These gases are expelled at high speed, stretching, cooling, and ultimately extinguishing the arc, thereby interrupting the fault current and protecting the lines and connected electrical equipment.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What should be noted when selecting and installing GIS voltage transformers?
What should be noted when selecting and installing GIS voltage transformers?
In power systems, voltage transformers in GIS (Gas Insulated Switchgear) play a crucial role in voltage measurement and relay protection. Selecting the right model and installing it correctly is vital for the stable operation of the equipment. The following points should be noted regarding selection and installation.I. Key Points for Selection(1) Matching Rated ParametersVoltage Level: It must be consistent with the voltage level of the GIS system. For example, 110kV and 220kV GIS systems requir
James
07/08/2025
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
What are the causes of the breakdown and burning of the 35 kV GIS voltage transformer?
1. Accident Overview1.1 Structure and Connection of 35kV GIS Switchgear Voltage TransformerThe ZX2 gas-insulated double-bus switchgear, manufactured in March 2011 and officially put into operation in July 2012, is configured with two groups of bus voltage transformers (PTs) for each bus section. The two PT groups of the same bus section are designed in one switchgear cabinet with a width of 600 mm. The three-phase PTs are arranged in a triangular formation at the bottom of the cabinet.The PTs ar
Felix Spark
07/08/2025
What Are the Steps for Error Testing GIS Voltage Transformers?
What Are the Steps for Error Testing GIS Voltage Transformers?
Hey everyone, I'm Oliver, and I've been working with current transformers (CTs) and voltage transformers (VTs) for 8 years.From assisting my mentor on site to leading high-voltage testing teams and conducting error calibrations independently, I’ve dealt with all kinds of instrument transformers — especially those used in GIS systems. The error test for voltage transformers is something I perform regularly.A few days ago, a friend asked me:“Oliver, how exactly do you perform an
Oliver Watts
07/08/2025
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
An GIS Equipment Explosion Accident Caused by PT Secondary Wiring Errors
1. Accident OverviewA newly - built 110kV substation’s GIS exploded during commissioning due to a PT secondary circuit short - circuit. Though the cause was simple, consequences were severe, warranting reflection.2. Accident ProcessOn the power - transmission day:The upper - level power supply charged the 110kV GIS (a combined appliance).20s after closing the incoming switch and first live - impacting the 110kV bus, white smoke emerged between the PT compartment and control cabinet.Within
Felix Spark
07/08/2025
Operation Method for PT Resonance in 500kV GIS Switching Station
Operation Method for PT Resonance in 500kV GIS Switching Station
1. Causes of ResonanceA 500kV GIS switching station is designed following the principle of “primary equipment intelligence and secondary equipment networking”. The PT high - voltage side has no disconnector and is directly connected to the bus GIS. Through the analysis of fault recording diagrams, when the 5021 circuit breaker opens, the fracture capacitance and PT form a series circuit. Moreover, the bus voltage, after being paralleled by the PT inductance, shows inductive character
James
07/08/2025
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
What to Pay Attention to When Selecting and Installing GIS Current Transformers?
Hi everyone, I'm James, and I've been working with current transformers (CTs) for 10 years. Today, I’ll talk about what you need to watch out for when selecting and installing GIS current transformers.Part 1: Key Considerations During Selection1. Accuracy ClassProtection-grade CTs: Used for relay protection — focus on overload capacity and transient response.Metering-grade CTs: Used for billing purposes — require high accuracy, usually 0.2S or 0.5S class.2. Rated Primary Curren