• DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
discuss personally
Model
DS7B-800D/5000-63
DS7B-550D/3150-63
DS7B-420D/3150-63
DS7B-363D/5000-63
DS7B-363D/3150-63
DS7B-252D/5000-63
DS7B-252D/4000-63
DS7B-252D/3150-50
DS7B-252D/2500-50
DS7B-252D/2000-50
DS7B-145D/2000-40
DS7B-145D/1250-31.5
DS7B-72.5D/4000-50
DS7B-72.5D/3150-50
DS7B-72.5D/2500-50
DS7B-72.5D/2000-40
DS7B-72.5D/1250-40
Basic info
Brand ROCKWILL
Model NO. DS7B 72.5kV 145kV 252kV 363kV 420kV 550kV 800kV High voltage disconnect switch
Rated voltage 145kV
Rated normal current 2000A
Rated frequency 50/60Hz
Rated peak value withstand current 100kA
Rated short-time withstand current 40kA
Series DS7B
Product Detail

Product introduction

DSDS7B series Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. it is used for breaking or correcting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance currant and is able to open and close the bus to switch current.

This product has three posts with horizontal open breaks. JW10 grounding switches may be attached to the product at one or two sides 72.5-252kV Switch Disconnector adopts C2 or SRCJ2 manual actuator to realize the tri-pole linkage. The earthing switch adopts CS11 or SRCR manual actuator to actualize tr-pole linkage,.363kV disconnect switch adopts SRCJ2 motor's actuator to realize the single pole operation; while the earthing switch takes SRCS manual actuator or SRCJ2 motor's actuator to realize the single pole operation and also tri-pole linkage.

This product has been verified by the Chinese competent authority as having uniqueness in design and reaching international advanced level of similar products.

GW7B Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator and conductive part. Three insulating posts are installed onto a long base, with two static contacts mounted at both ends to fix the top of the insulating post, and the conductive knife switch mounted onto the top of the rotating insulating post in between.

The actuator drives the rotating post in the middle to bring the conductive knife switch circumgyrate to open or close the breaker by contacting or detaching the static contacts fixed on the both ends of the post, Two horizontal insulating open breaks in series will appear at the closing moment.

In the opening and closing process, the conductive knife switch will horizontally swing and auto-rotate, with the aid of the turnover mechanism, to reduce the operating force and impact that occur in the opening and closing process and to improve the contact’s ability self-cleaning.

Main characteristic

  • The Switch Disconnector is of the turnover-type, and the conductive tube will move in two steps. At the closing moment, the conductive tube will rotate by some 70" on the horizontal surface, When the contacts at both ends are blocked up after having been placed in the static contact base, the turnover mechanism will drive the conductive tube to auto-rotate by about 45° when the movable contact will be in reliable contact with the touch finger. This process requires small operating force, thus causing no impacts on the insulators fixed at both ends. The main contact has the self-cleaning ability.
  • One end of the U-shaped finger within the static contact is fixed onto the contact base, forming a fixed connection and ensuring the reliable conduction; while the other end will produce contact pressure on the movable contact as a result of the influence of external spring and the own elastic force of the contact finger, and the gripping force will automatically increase when the short-circuit current passes through the contact. The contact spring is made of stainless steel and is equipped with insulating gasket, The spring will not corrupt nor shunt.
  • Provide one-key sequential control "double confirmation" function expansion.
  • The rotating parts of the disconnect switch are designed to be free of maintenance. The rotating base is designed into a closure structure which denies the access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden.
  • 363kV and above earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact, The conductive rod for grounding will move in twosteps at the moments of opening and closing. At the moment of closing, the conductive rod will rotate vertically and rise up lo the fixed contact, and then automatically plug itself into the star-shaped contact, By doing so, the contact will be made reliable and be able to sustain the heavy short-circuit current.

Main technical parameters

Order notice 

Product model, rated voltage, rated current, rated short-time withstand current, creepage distance and method of combination must be specified at the goods ordering time;

The methods of attaching earthing switches to Switch Disconnectores (left, right and both left and right);

Note: the way to judge the method of grounding: when one faces the name plate, the left grounding will be confirmed if the earthing switch is at the left hand side, and right grounding if at the right hand side;

The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch;

Current transformers are ordered by purchasers; however, it must be ensured that fixed contacts can be mounted onto such transformers:

When the Switch Disconnector is used at the incoming and outgoing terminals of the substation in the double loop parallel overhead power transmission line, if the earthing switch requires the opening/closing induction current, then such requirement shall be specified, Besides, the parameters and the side at which the earthing switch is set shall be defined. (Special notice: Not all earthing switches attached to the earthing switches and disconnect switches at the substation shall require the opening/closing induction current.)

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the common failures in single-phase distribution transformers?
What are the common failures in single-phase distribution transformers?
Single - phase distribution transformers, as crucial voltage transformation and power distribution equipment in the power system, are widely used in rural power grids, low - voltage residential areas, and areas with concentrated single - phase loads.With the continuous increase in the proportion of single - phase loads in the distribution network, the failure rate of single - phase transformers has also increased. Timely identification and handling of these faults are of great significance for e
Felix Spark
06/18/2025
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Comprehensive Analysis of Single-Phase Distribution Transformer Technologies in Multiple Application Scenarios
Introduce the 10 kV line to the load center. Following “small capacity, dense points, short radius”, adopt the new single - phase distribution mode, featuring notable low - voltage line loss reduction, high power quality, and reliability. By comparing the economy and reliability of single - phase vs three - phase transformers in different scenarios, this paper analyzes their applicable scope and application suggestions.Single - phase transformers are classified by distribution mode:
Echo
06/18/2025
What are the technical features and applications of single-phase distribution transformers?
What are the technical features and applications of single-phase distribution transformers?
1 Technical Features of Single - phase TransformersFrom the operation practice of foreign distribution networks, it is known that single - phase transformers are quite widely applied. Compared with three - phase transformers, they have unique advantages, which are specifically reflected as follows:1.1 Simple StructureThis characteristic makes that, when using the same materials, for single - phase transformers with the same capacity, their no - load losses are lower than those of three - phase t
Echo
06/17/2025
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
Application Analysis of High-Voltage Single-Phase Distribution Transformers in Power Distribution Networks
1. Safety Hazards in Substation Operation1.1Transformer FailuresTransformers are critical substation equipment and maintenance focal points. Loose/defective components often cause malfunctions, while internal damage (e.g., oil tank impurities/water/bubbles) triggers partial discharge, risking major losses during outages.1.2 Overvoltage RisksOutdoor overvoltage threatens equipment. Lightning-induced impulse currents alter transformer electromagnetic energy, and circuit breaker misoperations cause
Echo
06/17/2025
Prototype Development of 20 kV Single-Phase Distribution Transformer
Prototype Development of 20 kV Single-Phase Distribution Transformer
1. Design of 20 kV Single - phase Distribution Transformer20 kV distribution systems usually adopt cable lines or mixed cable - overhead line networks, and the neutral point is mostly grounded through a small resistance. When a single - phase grounding occurs, there will be no problem that the phase voltage will rise by more than √3 times as in the case of a single - phase fault in a 10 kV system. Therefore, the single - phase distribution transformer of the 20 kV system can adopt the type
Dyson
06/17/2025
Single-Phase Transformer with High Lightning Impulse Withstand Capability
Single-Phase Transformer with High Lightning Impulse Withstand Capability
1 IntroductionTo ensure the safe operation of railways and reduce the risk of lightning damage to railway telecommunication control systems, the author has specially researched and designed a single - phase series transformer with a relatively high impulse voltage withstand level, with the model number D10 - 1.2 - 30/10. This transformer is equipped with an oil conservator and adopts a fully sealed structure (it can also be designed as a dry - type structure according to actual needs). This seri
Dyson
06/17/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放