• 40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)
40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)
discuss personally
Model
ZHW58A-72.5/4000-40
ZHW58A-72.5/3150-31.5
ZHW58A-40.5/4000-40
ZHW58A-40.5/2500-31.5
Basic info
Brand Wone
Model NO. 40.5(72.5)kV Hybrid GIS
Rated voltage 40.5kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 40kA
Series ZHW58A-40.5(72.5)
Product Detail

Product introduction:

ZHW58A series was originally designed to meet the needs of power construction and hybrid product development, and its main application scenario is to meet the needs of 35-500KV substation expansion; At present, ZHW58A-40.5/72.5 products have reached the leading level at home and abroad in terms of technical advancement and quality reliability.

Main characteristic:

  •  Current transformers, isolation, grounding switch combination, compact, lightweight design, which can realize the whole transportation, save area, relative AlS station save covers an area of 70%, suitable for power plant and substation construction, expansion or reconstruction project and railway electrification construction, especially suitable for old substation upgrading, reduce the construction difficulty and investment scale.

  • CT is arranged on two sides of the circuit breaker (different from the structure of mainstream manufacturer’s' similar products, complying with the requirement "blind area of main protection shall be avoided in the configuration of protective current transformer and the allocation of secondary winding" as specified in the Technical specifications of Relay Protection and Safety Automatic Device, improving the reliability of power supply.

  • The product also adopts straight-through CT, completely solving problems such as excess moisture and low insulation margin and promoting the insulation resistance and reliability of the product.

  •  The product is configured with a grounding switch on equipment side and line side in a built-in way, with reliable earthing that prevents safety hazards in maintenance.

  • The circuit breaker adopts light-spring operating mechanism and aluminum frame of integral casting. It’s closing-opening springs adopt spiral dual-pressure spring, with a compact and indefatigable structure, realizing a mechanical life of 10000compressions.

  •  Aviation plugs are used to connect CB, DES & ES mechanism cases and control cabinet, facilitating field installation and commissioning.

  •  The structure of three-position disconnecting/grounding switch is stable and reliable.

  •  The inlet and outlet lines are connected to the equipment through bushings. Composite insulation bushings and porcelain bushings can be selected., Compared with GlS equipment, the enclosed bushings are omitted, and theSF6 gas consumption is less (less than 50% of GiS consumption), which is green and economical.

Main technical parameters:

image.png

Order Notice:

  • Application working condition (incoming/outgoing line, main transformer or PT interval);

  • Rated electrical parameters (voltage, current, breaking current and so on);

  • Conditions of use environment (ambient temperature, altitude and class of environmental pollution);

  • Control voltage of operating mechanism and motor voltage;

  • Quantity. current ratio, grade combination and secondary load of current transformer;

  • Name and quantity of spare products, spare parts & special tools and equipment (to be ordered separately).

What are the structural characteristics of hybrid high-voltage gas-insulated switchgear? 

Hybrid Gas Insulation System:

  • Typically, a mixture of SF₆ and other gases (such as N₂, CF₄, etc.) is used as the insulating medium. This design aims to combine the properties of different gases. For example, SF₆ has excellent insulating and arc-quenching properties but poses environmental concerns due to its greenhouse effect. By mixing it with other gases, the amount of SF₆ can be reduced while maintaining good insulation performance. The insulation system consists of sealed gas compartments that enclose the high-voltage conductive parts, preventing contact with the external environment and ensuring reliable electrical insulation.

Compact Design Layout:

  • To fully utilize the insulating properties of the hybrid gas, the internal structure of the equipment is designed to be compact. Various components of the switchgear, such as circuit breakers, disconnect switches, earthing switches, and busbars, are carefully arranged to minimize the overall size of the equipment. For example, compact circuit breaker designs and optimized busbar layouts enable efficient electrical connections and functional integration within a limited space.

Reliable Sealing Structure:

  • To ensure good insulation performance, the hybrid gas must be maintained at specific pressure and purity levels. Therefore, the equipment features highly reliable sealing structures. High-quality sealing materials (such as rubber O-rings, metal gaskets, etc.) and sealing techniques are used to ensure the airtightness of the gas compartments and prevent gas leakage. Additionally, the sealing structure must withstand temperature changes, mechanical vibrations, and other factors, maintaining stable sealing performance over the long term.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!