• 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
  • 2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
2.4KWh-10.24KWh Rack type energy storage battery(Industrial&Commercial energy storage)
$9828.00
Model
C48200
C48200
C48200
C48200
C48100
C48100
C48100
C48100
C4850
C4850
C4850
C4850
Basic info
Brand POWERTECH
Model NO. Rack type energy storage battery
Energy storage capacity 10.24kWh
Cell quality Class A
Series Industrial&Commercial energy storage
Product Detail

DCK-en.png                                    

Peculiarity

  • High energy density.

  • Equipped with BMS battery management system, longer cycle life.

  • Beautiful appearance; Standard rack specifications, free combination, easy installation.

  • The panel integrates a variety of interfaces, supports multiple protocols, and ADAPTS to most photovoltaic inverters and energy storage converters.

  • Can be customized adjustment management battery charging and discharging strategy.

  • Modular design, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months. 

What are the characteristics of rack-mounted energy storage batteries?

  • High integration:All components (such as battery modules, battery management system (BMS), inverter, energy management system (EMS), etc.) are integrated in one or more standard racks, which is convenient for transportation and on-site installation.The racks usually follow certain standard sizes, such as the standard server cabinet with a width of 19 inches.

  • Modular design:The rack-mounted energy storage battery allows users to add or remove specific modules as needed to expand or reduce the capacity of the energy storage system.The energy storage units in each rack can operate independently or be combined into a larger energy storage system in parallel or in series.

  • Standardized interfaces:The rack-mounted design usually adopts standardized interfaces, making components of different brands or models interchangeable or compatible, reducing the difficulty of system integration.

  • Easy installation and maintenance:The rack-mounted design makes the installation of the energy storage system very simple. Only the rack needs to be placed in an appropriate position and necessary electrical connections are made.During maintenance, each module can be easily accessed for inspection or replacement.

  • High space utilization:The design of standard racks can maximize space utilization, enabling the energy storage system to achieve a high energy storage density in a limited space.

  • Remote monitoring and management:The rack-mounted energy storage system usually integrates remote monitoring and management functions, and the system can be monitored and controlled in real time through the Internet or a dedicated network.This characteristic is very important for energy storage applications that require remote operation and maintenance.

  • Environmental adaptability:The rack-mounted design can integrate environmental conditioning equipment such as temperature control and humidity control to ensure that the battery operates under optimal working conditions.The rack itself can also be designed with characteristics such as dustproof and waterproof to improve the environmental adaptability of the system.

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!