• 27kV 15.5kV outdoor vacuum Single-phase recloser
27kV 15.5kV outdoor vacuum Single-phase recloser
discuss personally
Model
RWDRC
Basic info
Brand ROCKWILL
Model NO. 27kV 15.5kV outdoor vacuum Single-phase recloser
Rated frequency 50/60Hz
Rated line charging current 10A
IP grade IP66
Series RWDRC
Product Detail

Description :

The RWDRC series of single-phase reclosers are designed in accordance with IEC 62291-111-2019 (IEEE C37.60-2018). They are distribution network solution products that integrate multiple technologies such as current protection, communication, and self-power supply from line current.In terms of fault positioning, the device uses a variety of advanced technical means, such as traveling wave ranging and impedance method.

When a cable fault occurs, these technologies can quickly and accurately determine the location of the fault point with a very small margin of error. This greatly shortens the time for fault troubleshooting and repair, reducing the power - outage time and its impact on users.

This product is suitable for the protection of branch lines of overhead lines in the distribution network or the protection of user boundaries. When a permanent fault occurs on the line, it can quickly cut off the fault to prevent the fault from spreading to the main line. When a temporary fault occurs on the line, the line power supply can be restored through multiple reclosing operations, reducing the power outage time and improving the reliability of power supply.

Main function introduction:

  • Fault Detection and Isolation

  • Reclosing Function

  • Multiple Reclosing Control

  • Protection Coordination Function

Technology parameters:

image.png

Vacuum arc-extinguishing chamber parameters

image.png

Magnetic force actuator parameters

image.png

Current sensor parameters

image.png

Structure diagram

image.png

image.png

Device structure:

image.png

image.png

Installation schematic diagram

image.png

image.png

Q:What is a recloser used for?

A:A recloser is an electrical device used in power distribution systems. It is primarily used to automatically reconnect an electrical circuit after a fault has been detected and cleared. This helps to minimize power outages and improve the reliability of the power supply by quickly restoring electricity to the affected area.

Q: What is the difference between a breaker and a recloser?

A:A breaker is a device that can open and close a circuit under normal and fault conditions to protect the system from overloads and short - circuits. A recloser, however, is designed to automatically close the circuit a few times after a fault, in the hope that the fault was temporary, reducing outage time.

Q:What is a single-phase appliance?

A: A single - phase appliance is an electrical device that operates on a single - phase power supply. It uses the alternating current provided by a single - phase circuit, which has one active wire and one neutral wire. Common examples include most household appliances like refrigerators, televisions, and microwaves, which are designed to work with the standard single - phase power in homes.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Common faults of indoor AC high-voltage vacuum circuit breakers
Common faults of indoor AC high-voltage vacuum circuit breakers
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
A vacuum circuit breaker is a type of circuit breaker in which both the arc - extinguishing medium and the insulating medium in the gap between the contacts after arc - extinction are vacuum. As a protection and control unit for power equipment and power - driven equipment in industrial and mining enterprises, indoor AC high - voltage vacuum circuit breakers have diverse applications and can be installed in fixed cabinets, middle - mounted cabinets, and double - layer cabinets. As a crucial elec
Felix Spark
06/06/2025
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
VS1 Indoor High - Voltage Vacuum Circuit Breaker Fault Analysis and Improvement MeasuresThe VS1 indoor high - voltage vacuum circuit breaker is an indoor switching device used in 12 kV power systems. Due to its excellent performance, it is especially suitable for places that require frequent operation at rated working current or multiple interruptions of short - circuit current. The operating mechanism of the VS1 indoor high - voltage vacuum circuit breaker is integrated with the circuit breaker
Felix Spark
06/05/2025
Generator Protection – Types of Faults & Protection Devices
Generator Protection – Types of Faults & Protection Devices
Common Generator Faults and Protection SystemsClassification of Generator FaultsGenerator faults are primarily categorized into internal and external types:Internal Faults: Arise from issues within generator components.External Faults: Stem from abnormal operating conditions or external network issues.Faults in prime movers (e.g., diesel engines, turbines) are mechanical in nature and defined during equipment design, though they must integrate with generator protections for tripping purposes.Typ
Edwiin
06/05/2025
Classification of Electric Power Distribution Network Systems
Classification of Electric Power Distribution Network Systems
The typical electric power system network is categorized into three main components: generation, transmission, and distribution. Electric power is produced in power plants, which are often located far from load centers. As a result, transmission lines are employed to deliver power over long distances.To minimize transmission losses, high-voltage power is used in transmission lines, and the voltage is reduced at the load center. The distribution system then delivers this power to end-users.Types
Edwiin
06/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放