• 27kV MV outdoor Auto Circuit vacuum recloser
  • 27kV MV outdoor Auto Circuit vacuum recloser
  • 27kV MV outdoor Auto Circuit vacuum recloser
  • 27kV MV outdoor Auto Circuit vacuum recloser
27kV MV outdoor Auto Circuit vacuum recloser
$5000.00
Model
RCW-E27G/1250-25
RCW-E27G/800-20C
RCW-E27G/800-20
RCW-E27G/630-16C
RCW-E27G/630-16
RCW-E27G/400-12.5C
RCW-E27G/400-12.5
Basic info
Brand ROCKWILL
Model NO. 27kV MV outdoor Auto Circuit vacuum recloser
Rated voltage 27kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 70kV/min
Rated lightning impulse voltage 150kV
manual closing No
Mechanical lock No
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for allvoltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’s recloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

image.png

image.png

External dimensions:

企业微信截图_17103058136732.png


Environmental requirement:

image.png

Product show:

正方形最新环氧聚脂带手和.png

 What are the key points for the selection of outdoor vacuum reclosers?

  • System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.

  • Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.

  • Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.

  • Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.

  • Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
Echo
06/06/2025
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
A vacuum circuit breaker is a type of circuit breaker in which both the arc - extinguishing medium and the insulating medium in the gap between the contacts after arc - extinction are vacuum. As a protection and control unit for power equipment and power - driven equipment in industrial and mining enterprises, indoor AC high - voltage vacuum circuit breakers have diverse applications and can be installed in fixed cabinets, middle - mounted cabinets, and double - layer cabinets. As a crucial elec
Felix Spark
06/06/2025
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
VS1 Indoor High - Voltage Vacuum Circuit Breaker Fault Analysis and Improvement MeasuresThe VS1 indoor high - voltage vacuum circuit breaker is an indoor switching device used in 12 kV power systems. Due to its excellent performance, it is especially suitable for places that require frequent operation at rated working current or multiple interruptions of short - circuit current. The operating mechanism of the VS1 indoor high - voltage vacuum circuit breaker is integrated with the circuit breaker
Felix Spark
06/05/2025
Generator Protection – Types of Faults & Protection Devices
Generator Protection – Types of Faults & Protection Devices
Common Generator Faults and Protection SystemsClassification of Generator FaultsGenerator faults are primarily categorized into internal and external types:Internal Faults: Arise from issues within generator components.External Faults: Stem from abnormal operating conditions or external network issues.Faults in prime movers (e.g., diesel engines, turbines) are mechanical in nature and defined during equipment design, though they must integrate with generator protections for tripping purposes.Typ
Edwiin
06/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放