• 15kV/1250A MV outdoor vacuum Auto Circuit recloser
15kV/1250A MV outdoor vacuum Auto Circuit recloser
$5000.00
Model
RCW-E15M/1250-25C
RCW-E15M/1250-25
RCW-E15M/800-20C
RCW-E15M/800-20
RCW-E15M/630-16C
RCW-E15M/630-16
RCW-E15M/400-12.5C
RCW-E15M/400-12.5
RCW-E15M/400-12.5
RCW-F15M/1250-25C
RCW-F15M/1250-25
RCW-F15M/800-20C
RCW-F15M/800-20
RCW-F15M/400-12.5C
RCW-F15M/400-12.5
RCW-F15M/630-16
RCW-F15M/630-16C
Basic info
Brand ROCKWILL
Model NO. 15kV/1250A MV outdoor vacuum Auto Circuit recloser
Rated voltage 15kV
Rated normal current 630A
Rated short circuit breaking current 16kV
Power frequency withstand voltage 36kV/min
Rated lightning impulse voltage 110kV
manual closing Yes
Mechanical lock
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overheaddistribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’srecloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters

image.png

image.png


Environmental requirement:

image.png

Product show:

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

What is the vacuum arc extinguishing fault of outdoor vacuum recloser and its solution?

Vacuum Arc Quenching Chamber Faults:

  • Decreased Vacuum Level: This is a common issue with vacuum arc quenching chambers. The vacuum arc quenching chamber relies on a high-vacuum environment to extinguish arcs. If the vacuum level decreases, its insulation performance and arc-quenching ability will significantly deteriorate. The causes of decreased vacuum levels can include poor sealing, such as aging or damaged sealing materials, or tiny leaks present during the manufacturing process. When the vacuum level drops to a certain extent, incomplete arc extinction may occur during current interruption, leading to arc reignition and subsequent line faults.

  • Contact Wear: During frequent opening and closing operations, the contacts of the vacuum arc quenching chamber can wear down due to arc erosion. Contact wear increases contact resistance, which can lead to severe heating of the contacts when normal current passes through, affecting the normal operation of the equipment. Additionally, during fault current interruption, the contacts may not withstand the high current, resulting in contact welding or failure to interrupt the current.

Solutions for Vacuum Arc Quenching Chamber Faults:

Vacuum Level Decrease:

  • Detect Vacuum Level: Use specialized vacuum level detection instruments, such as vacuum level testers, to regularly check the vacuum level of the vacuum arc quenching chamber. Once the vacuum level is found to be below the specified value, the vacuum arc quenching chamber should be replaced promptly.

  • Replace Seals: If you suspect that poor sealing is causing the decrease in vacuum level, inspect and replace the seals. When replacing seals, ensure that you use high-quality, compatible sealing materials and follow the correct installation procedures to prevent further leakage.

Contact Wear:

  • Regular Inspection: Regularly inspect the wear condition of the contacts through observation windows or by disassembling the device. Based on the degree of wear, if the wear exceeds the specified limit, the contacts should be replaced promptly.

  • Optimize Operating Parameters: Analyze the causes of contact wear, such as whether it is due to frequent operations or excessive operating current. If the issue is frequent operation, consider optimizing the recloser's reclosing strategy to reduce unnecessary opening and closing operations. If the issue is excessive operating current, check the line load conditions, adjust the protection settings, and avoid subjecting the contacts to excessive current impacts.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
What are the contents of operation and maintenance for the VS1 indoor high-voltage vacuum circuit breaker?
VS1 - Type Indoor High - Voltage Vacuum Circuit BreakerThe VS1 - type indoor high - voltage vacuum circuit breaker is an indoor device for three - phase AC 50Hz with a rated voltage of 12kV. It is used for the control and protection of electrical facilities in industrial and mining enterprises, power plants, and substations. The circuit breaker arranges the main circuit and the operating mechanism on a special - shaped frame in a front - rear manner, that is, an integral layout. This structural
Echo
06/06/2025
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
What are the common faults of indoor AC high-voltage vacuum circuit breakers?
ZN63A Indoor AC High-Voltage Vacuum Circuit BreakerThe ZN63A indoor AC high-voltage vacuum circuit breaker is a three-phase AC 50 Hz, 12 kV indoor device, used for starting, stopping, controlling, and protecting high-voltage motors of 10,000-ton free forging presses. AC high-voltage vacuum circuit breakers play a critical role in enterprise production. Timely and accurate resolution of their faults to quickly restore production is essential for enterprise development. During the start/stop of hi
Felix Spark
06/06/2025
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Load Frequency Control (LFC) & Turbine Governor Control (TGC) in Power System
Brief Introduction to Thermal Generating UnitsElectricity generation relies on both renewable and non - renewable energy resources. Thermal generating units represent a conventional approach to power production. In these units, fuels such as coal, nuclear energy, natural gas, biofuel, and biogas are combusted within a boiler.The boiler of a generating unit is an extremely complex system. In its simplest conception, it can be visualized as a chamber whose walls are lined with pipes, through which
Edwiin
06/06/2025
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
Analysis and Discussion on the Main Shaft Fault of Vacuum Circuit Breaker in EIB Mechanism
A vacuum circuit breaker is a type of circuit breaker in which both the arc - extinguishing medium and the insulating medium in the gap between the contacts after arc - extinction are vacuum. As a protection and control unit for power equipment and power - driven equipment in industrial and mining enterprises, indoor AC high - voltage vacuum circuit breakers have diverse applications and can be installed in fixed cabinets, middle - mounted cabinets, and double - layer cabinets. As a crucial elec
Felix Spark
06/06/2025
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
Analysis of a Burning - out Fault of VS1 Vacuum Circuit Breaker
VS1 Indoor High - Voltage Vacuum Circuit Breaker Fault Analysis and Improvement MeasuresThe VS1 indoor high - voltage vacuum circuit breaker is an indoor switching device used in 12 kV power systems. Due to its excellent performance, it is especially suitable for places that require frequent operation at rated working current or multiple interruptions of short - circuit current. The operating mechanism of the VS1 indoor high - voltage vacuum circuit breaker is integrated with the circuit breaker
Felix Spark
06/05/2025
Generator Protection – Types of Faults & Protection Devices
Generator Protection – Types of Faults & Protection Devices
Common Generator Faults and Protection SystemsClassification of Generator FaultsGenerator faults are primarily categorized into internal and external types:Internal Faults: Arise from issues within generator components.External Faults: Stem from abnormal operating conditions or external network issues.Faults in prime movers (e.g., diesel engines, turbines) are mechanical in nature and defined during equipment design, though they must integrate with generator protections for tripping purposes.Typ
Edwiin
06/05/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放