• ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
  • ​Digital Multi-function Power Meter
​Digital Multi-function Power Meter
$15.00
Model
RQY-72E
RQY-80E
RQY-96E
Basic info
Brand Wone Store
Model NO. ​Digital Multi-function Power Meter
size 72*72mm
Series RQY
Product Detail

The Digital Multi-function Power Meter is a modern power monitoring core device that integrates high-precision measurement, comprehensive monitoring, and intelligent communication. Utilizing a clear and intuitive digital display interface, it provides full-spectrum real-time data of the power system for you. It is the ideal choice for realizing fine-grained energy consumption management, enhancing operational efficiency, and ensuring power supply security in industrial automation, building management, data centers, and power distribution systems.

Core Functions, At a Glance:

  • Precision Measurement: Monitors critical electrical parameters including three-phase/single-phase voltage, current, active/reactive/apparent power, power factor, frequency, etc., in real-time, with leading accuracy (high precision).

  • Energy Metering: Accurately meters active energy and reactive energy (import/export), providing a reliable basis for energy consumption analysis and billing.

  • Power Quality Insight: Offers optional monitoring of power quality parameters such as harmonic content, voltage/current unbalance, etc., aiding in optimizing power supply quality.

  • Clear Display: Employs a high-brightness LED or LCD display (typically dual-row or multi-row), presenting data clearly and intuitively with rich information, facilitating fast on-site reading.

  • Flexible Communication: Integrates standard communication interfaces such as RS485, supporting mainstream industrial protocols like Modbus-RTU, Profibus, CANopen (depending on model configuration), enabling seamless integration into SCADA, EMS, BMS and other systems for remote monitoring and data acquisition (SCADA).

  • Intelligent Alarming: Provides out-of-limit alarm functionality, promptly detecting potential risks such as voltage anomalies or current overload.

  • Data Logging: Certain models feature historical data logging capability, facilitating history tracing and analysis.

Product Advantages, Worthy of Trust:

  • High Accuracy and Reliability: Ensures stable measurements and accurate, trustworthy data, meeting high-standard application requirements.

  • Comprehensive Function Integration: Addresses multiple monitoring needs with a single meter, reducing installation complexity and cost.

  • Convenient and Flexible Installation: Offers multiple form factors (square or DIN-rail mounted), allowing easy adaptation to various distribution panels/cabinets (switchboard/cabinet).

  • Powerful Compatibility: Utilizes standard communication protocols, ensuring easy integration with existing systems.

  • Rugged and Durable: Features an industrial-grade design, wide operating temperature range (e.g., -25°C to +70°C), and strong interference resistance (high immunity).

  • Assists Energy Efficiency Enhancement: Provides precise data support for energy audits and energy-saving renovations.

Technical Specifications:

Parameter Specification
Connection Three-phase four-wire Y34 / Three-phase three-wire V33
Signal Input - Voltage Range 400V / 100V
Signal Input - Voltage Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Voltage Consumption < 1VA
Signal Input - Current Range 5A / 1A
Signal Input - Current Overload Continuous: 1.2x, Instantaneous: 2x
Signal Input - Current Consumption < 1VA
Frequency 40-65Hz
Power Supply AC220V (default) or AC/DC 80-270V
Energy Pulse Output Passive optocoupler collector output
Pulse width: 80ms ±20%
Communication • Interface: RS485 (physically isolated)
       • Protocol: MODBUS-RTU
       • Baud rate: 1200-9600 bps
       • Parity: N81/E81/O81
Analog Output • Range: 0/4-20mA or 0-5/10V
       • Configurable variables via programming
Relay Output • Type: Programmable alarm/trip relay
       • Rating: 5A/250V AC, 5A/30V DC
       • Trigger sources: Battery alarm, DI, AI, remote
Digital Input (DI) • Type: Dry contact
       • Function: Programmable alarm mapping
Accuracy Class • Voltage/Current: 0.5
       • Active Energy: 0.5S
       • Reactive Energy: 1.0
       • Frequency: ±0.1Hz
Display High-definition LCD (integrated nixie tube type)
Environmental • Operating: -10°C to +55°C
       • Storage: -20°C to +75°C
Safety Standards • Insulation resistance: >5MΩ (signal/power/earth)
       • Dielectric strength: >2kV AC (signal/power/output)

Wiring diagram:
  Wiring diagram.png


Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!