• Wind Power Equipment Box-type Transformer(Prefabricated Substation)
Wind Power Equipment Box-type Transformer(Prefabricated Substation)
discuss personally
Model
ZG(F)S11-1000kVA
Basic info
Brand ROCKWILL
Model NO. Wind Power Equipment Box-type Transformer
Rated voltage 40.5kV
Series Compact Substation
Product Detail

Product overview:

  • Wind turbine substation is to send the electricity generated by the wind turbine to the grid or users, so as to complete the task of wind power generation. Friends WONE wind box products is the transformer, oil-immersed load switch and high voltage fuse is installed in the fuel tank, transformer oil as the medium of electrical insulation products and cooling medium and low voltage side configuration necessary electric protection components, products with intelligent, reliable operation, small volume, light weight and easy installation and use, etc.

  • Rated AC frequency 50Hz/60HZ, input voltage 0.8kV, 0.9kV, maximum working voltage up to 40.5kV, withstand lightning strike 200KV.

  • Main application: Wind power industry.

  • Standards: IEC61400 series, GB/T17467, etc.

Product advantages:
Leading technology:

  • Standard anti-corrosion and salt spray environment scheme, meet the strict environmental requirements of the site.

  • Can be composed of vacuum circuit breaker and sulfur hexafluoride ring network cabinet or all sulfur hexafluoride ring network cabinet.

  • Prefabricated, electrified and touchable silicone rubber cable end ensures personal safety.

  • Can be equipped with multiple SF6 load switches, flexible and diverse wiring modes, branch outlet up to eight circuits.

  • Compact design, optional lightning arrester, short circuit fault indicator. Current limiting fuse.

  • The relative pressure of SF6 in the air pack should not exceed 1.4bar. Air leakage is not more than 1%/ year, 30 years maintenance free.

  • Box type opening and closing should have perfect five anti-interlocking function to ensure personal safety .

Enclosure:

  • The whole use of 1.5-2mm double layer stainless steel box, service life can reach more than 30 years.

  • Laser CNC equipment cutting, drilling, bending, ensure processing accuracy.

  • External electrostatic epoxy powder coating, 30 years of paint.

  • Box surface has good anti-theft, box has IP3X protection, etc.

Processing and assembly:

  • Dust-free workshop to ensure insulation.

  • Assembly workers must be trained for at least 6 months.

  • Automatic terminal crimping machine for secondary wiring to ensure reliable wiring.

  • Bolt reinforcement using power tools to ensure proper torque.

  • The copper busbar is CNC cutting, punching and bending to ensure accuracy.

  • All kinds of experimental tests before delivery, to ensure the normal operation of equipment.

Product parameters:

  • Capacity: 2500kVA American box.

  • Rated voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 35kV.

  • Maximum operating voltage (kV) 38.5kV.

Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90

  •  Altitude (≤m) : 1000.

  •  solar radiation intensity (W/cm2) : 0.1.

  • Maximum ice thickness (mm) : 10.

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35.

  • Ground horizontal acceleration (M/S2) : 2.

  • Installation place: outdoor; 8. Pollution grade: ⅲ.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram, secondary loop system diagram and auxiliary circuit control mode.

  • Equipment layout and distribution room layout.

  • Brand and model of main electrical components of the equipment.

  • Incoming and outgoing lines.

  • Other special requirements can be negotiated with WONE you Electric.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!