• UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
UT15BMAX Digital multimeter
$66.00
Model
UT15BMAX
Basic info
Brand Wone
Model NO. UT15BMAX Digital multimeter
DC voltage 600.0mV/6.000V
AC voltage 600.0mV/6.000V
AC current 600.0µA/6000µA
DC current 600.0µA/6000µA
Series UT15BMAX
Product Detail

Description

UT15B MAX/UT17B MAX/UT18B MAX is a high-reliability True RMS digital multimeter with built-in VFD anti-interference start mode, 

which can filter the carrier frequency interference or various distortion voltage signals superimposed by the sine wave, 

and stably measure the output voltage and frequency of the inverter. 

Switching between entry frequency and duty cycle measurement under DC/AC function.

 The UT17B MAX/UT18B MAX is equipped with a 0.1°C partial temperature measurement function. 

The UT18B MAX has an LED measurement function that can measure up to 12V LEDs without distinguishing between positive and negative polarity. 

This series of products has full functions to achieve false detection protection of up to 30kVA energy, and the current gear is accidentally inserted into the input hole alarm, 

ensuring that users are safer and more assured in operation.

Industry applications

It is an indispensable measuring instrument for power electronics and other sectors. The main purpose is to measure voltage, current, and resistance. Generally, the multimeter can measure DC current, DC voltage, AC current, AC voltage, resistance and audio level, and some can also measure AC current, capacitance, inductance and some parameters of semiconductors.

Features

  • Large LCD 6000-bit analog-to-digital display, fast ADC/analog-to-digital converter.

  • Built-in VFD low-pass filtering, which can accurately measure distortion voltage and frequency conversion voltage.

  • The capacitance measurement is intelligent, and in the relative value measurement mode, the >6.2uF automatically exits the relative measurement mode.

  • VOLTAGE, CURRENT, AND RESISTANCE MEASUREMENTS CAPTURE MAXIMUM/MINIMUM (MAX/MIN) CHANGES (UT15B MAX/UT17B MAX).

  • Full-function false test protection, up to 1000V overvoltage impulse; And set the over-voltage and over-current alarm prompts.

  • The current gear is inserted into the input port by mistake to prompt an audible and visual alarm.

Technical parameters

UT15B MAX Technical Indicators
Basic Functions   Range Basic Accuracy
DC Voltage(V)  600.0mV/6.000V/60.00V/600.0V/1000V ±(0.4%+3)
AC Voltage(V) 600.0mV/6.000V/60.00V/600.0V/1000V ±(0.5%+5)
VFD(V) 600.0V ±(8%)
AC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
DC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
Resistance(Ω)  600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ/60.00MΩ  ±(0.5%+2)
Capacitance(F) 6.000nF/60.00nF~600.0µF/6000µF ±(2.0%+5)
Frequency(Hz)  10Hz~10MHz ±(0.1%+3)
Duty Cycle(%) 10Hz~10MHz ±(1.0%+4)


 Special Features
Maximum display 6000
Diode testing
On-off test
Data is kept 
Maximum/minimum values
Relative value
Secondary backlight (adjustable)
Automatic shutdown 
Low battery prompt 
Sound and light alarm prompt 
LED Testing -
False jack alarm 
Wake up the √ with any key
Safety class CATIII  CATⅢ600V
Certifications CE, UKCA, ETL CE、UKCA、ETL、RoHS

Basic parameters
Power supply  2*1.5V AA
Body color  426U+1797C
The weight of the body 455g
The body size  182mm*91mm*45mm
Standard packing color box + cloth bag
Standard package quantity 10 units
Standard package size  480×370×195mm
The gross weight of the standard box  about 9kg

Product show

企业微信截图_17156635842995.png

企业微信截图_17156635547984.png

企业微信截图_17156636101196.png

企业微信截图_17156636606870.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th
Oliver Watts
06/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放