• UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
  • UT15BMAX Digital multimeter
UT15BMAX Digital multimeter
$66.00
Model
UT15BMAX
Basic info
Brand Wone
Model NO. UT15BMAX Digital multimeter
DC voltage 600.0mV/6.000V
AC voltage 600.0mV/6.000V
AC current 600.0µA/6000µA
DC current 600.0µA/6000µA
Series UT15BMAX
Product Detail

Description

UT15B MAX/UT17B MAX/UT18B MAX is a high-reliability True RMS digital multimeter with built-in VFD anti-interference start mode, 

which can filter the carrier frequency interference or various distortion voltage signals superimposed by the sine wave, 

and stably measure the output voltage and frequency of the inverter. 

Switching between entry frequency and duty cycle measurement under DC/AC function.

 The UT17B MAX/UT18B MAX is equipped with a 0.1°C partial temperature measurement function. 

The UT18B MAX has an LED measurement function that can measure up to 12V LEDs without distinguishing between positive and negative polarity. 

This series of products has full functions to achieve false detection protection of up to 30kVA energy, and the current gear is accidentally inserted into the input hole alarm, 

ensuring that users are safer and more assured in operation.

Industry applications

It is an indispensable measuring instrument for power electronics and other sectors. The main purpose is to measure voltage, current, and resistance. Generally, the multimeter can measure DC current, DC voltage, AC current, AC voltage, resistance and audio level, and some can also measure AC current, capacitance, inductance and some parameters of semiconductors.

Features

  • Large LCD 6000-bit analog-to-digital display, fast ADC/analog-to-digital converter.

  • Built-in VFD low-pass filtering, which can accurately measure distortion voltage and frequency conversion voltage.

  • The capacitance measurement is intelligent, and in the relative value measurement mode, the >6.2uF automatically exits the relative measurement mode.

  • VOLTAGE, CURRENT, AND RESISTANCE MEASUREMENTS CAPTURE MAXIMUM/MINIMUM (MAX/MIN) CHANGES (UT15B MAX/UT17B MAX).

  • Full-function false test protection, up to 1000V overvoltage impulse; And set the over-voltage and over-current alarm prompts.

  • The current gear is inserted into the input port by mistake to prompt an audible and visual alarm.

Technical parameters

UT15B MAX Technical Indicators
Basic Functions   Range Basic Accuracy
DC Voltage(V)  600.0mV/6.000V/60.00V/600.0V/1000V ±(0.4%+3)
AC Voltage(V) 600.0mV/6.000V/60.00V/600.0V/1000V ±(0.5%+5)
VFD(V) 600.0V ±(8%)
AC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
DC Current(A) 600.0µA/6000µA /60.00mA/600.0mA/6.000A/10.00A ±(1.2%+3)
Resistance(Ω)  600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ/60.00MΩ  ±(0.5%+2)
Capacitance(F) 6.000nF/60.00nF~600.0µF/6000µF ±(2.0%+5)
Frequency(Hz)  10Hz~10MHz ±(0.1%+3)
Duty Cycle(%) 10Hz~10MHz ±(1.0%+4)


 Special Features
Maximum display 6000
Diode testing
On-off test
Data is kept 
Maximum/minimum values
Relative value
Secondary backlight (adjustable)
Automatic shutdown 
Low battery prompt 
Sound and light alarm prompt 
LED Testing -
False jack alarm 
Wake up the √ with any key
Safety class CATIII  CATⅢ600V
Certifications CE, UKCA, ETL CE、UKCA、ETL、RoHS

Basic parameters
Power supply  2*1.5V AA
Body color  426U+1797C
The weight of the body 455g
The body size  182mm*91mm*45mm
Standard packing color box + cloth bag
Standard package quantity 10 units
Standard package size  480×370×195mm
The gross weight of the standard box  about 9kg

Product show

企业微信截图_17156635842995.png

企业微信截图_17156635547984.png

企业微信截图_17156636101196.png

企业微信截图_17156636606870.png


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
Discussion on the Design of Low Zero-Sequence Impedance Grounding Transformers
With the expansion of power system scale and the cableization process of urban power grids, the capacitive current in 6kV/10kV/35kV power grids has significantly increased (generally exceeding 10A). As power grids at this voltage level mostly adopt neutral ungrounded operation mode, and the distribution voltage side of main transformers is usually in delta connection, lacking a natural grounding point, the arc during ground faults cannot be reliably extinguished, necessitating the introduction o
Dyson
06/11/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放