• Type 85C17 Analog Indicator Electrical Measuring Instrument
  • Type 85C17 Analog Indicator Electrical Measuring Instrument
  • Type 85C17 Analog Indicator Electrical Measuring Instrument
Type 85C17 Analog Indicator Electrical Measuring Instrument
$5.00
Model
85C17
Basic info
Brand Wone
Model NO. Type 85C17 Analog Indicator Electrical Measuring Instrument
type voltmeter
Input method DC
Series 85C17
Product Detail

Description

The fixed direct-acting analog indicator electric measuring instrument can display the change trend of the measurement, the reading is convenient, the cover is made of transparent plexiglass, and the card frame is installed.

The AC current and voltmeter in this series of instruments are suitable for measuring current and voltage in 50Hz AC circuitsMeasure; DC current and voltmeter are suitable for measuring current and voltage in DC circuits.In addition to separate use, it is mainly used for AC, DC transmission and distribution stations, power grids and other power systems and various switches Cabinets, power cabinets, control cabinets, compensation cabinets and other electrical devices are used as instrument panels

Industry applications

It is an important basis for the operation supervision of chemical power equipment by substation workers in the chemical industry, and can complete the acquisition and realization of basic data of power load statistics, production index calculation and technical material accumulation in chemical production. It is of great value for the stable and safe operation of the power system in chemical production.

In electrical measurement, the indication instrument of electrical measurement is an important part of the electrical measuring instrument, which can turn the measured electricity in the meter connected to the electrical measurement into a movable mechanical displacement, and can be directly read by the numerical value through the reaction of the mobile pointer connected to the scale . The abbreviation of the indicator instrument for electrical measurement is the indicator instrument, which can also be called the electrical and mechanical indicating instrument.

Features


  • The AC instrument adopts a magnetoelectric measuring mechanism and is equipped with an AC/DC measurement circuit to form a rectifier instrument. straight.

  • The flow meter consists of a magnetoelectric measuring mechanism and a measuring circuit.

Technical parameters

AC current, voltmeter range

Product type Unit Range
Access mode
AC meters A 0.05、0.1、0.2、0.3、0.5、2、2、3、5、7.5、10、15、20、30、50 Direct access
KA 1、2、3、5、7.5、10、 It is connected through a current transformer
V 3、5、7.5、10、15、20、30、50、60、75、100、120、150、200、250、300、450、500、600、 Direct access
KV 3.6、7.2、12、18、42、150、300、460
Access via external resistor

DC current, voltmeter range

DC current, voltmeter range Unit Range Access mode
DC meters mA 1、2、3、5、10、15、20、30、40、50、75、100、150、200、300、500 Direct access
A 1、2、3、5、7.5、10、15、20
5、7.5、10、30、30、50、75、100、150、200、300、500、750 Access via external shunt
KA 1、2、3、5、10 Direct access
V 3、5、7。5、10、15、20、30、50、60、75、100、120、150、200、250、300、450、500、600
KV 0.75、1、1.5 Access via external resistor

Dimensions

企业微信截图_17158387517386.png

Product show



091457126zxw.png

091457148fr7.png

201781893549334248.jpg



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th
Oliver Watts
06/09/2025
×
Inquiry
Download