Brand ROCKWILL
Model NO. Photovoltaic grid-connected isolation transformer
Rated frequency 50/60Hz
Rated capacity 180KVA
Series SGG
Product Detail

Product Overview:

Photovoltaic power generation inverter isolation transformers play a critical role in systems that harness solar energy via the photovoltaic effect at semiconductor interfaces, where solar cells serve as the core components. These cells are encapsulated and connected in series to form large-area modules, which, when integrated with power controllers, constitute a complete photovoltaic power generation device.
Designed primarily for solar inverter systems, photovoltaic transformers require high-efficiency performance to compensate for inherent energy conversion losses in photovoltaic setups. Their grid-side wiring configurations, such as Dyn11 and YD5 phase shift transformers with 120° phase displacement, ensure stable grid interconnection. To minimize no-load energy losses, these isolation transformers are typically operated during daylight hours and shut down at night.
Below are reference parameters for three-phase photovoltaic transformers:
Key Features:
  • Electrical Safety Isolation:Designed to achieve complete electrical separation between the photovoltaic system and the grid, preventing direct current (DC) leakage and reducing risks of electric shock. It blocks grid-borne harmonics and surges, ensuring clean power transmission.
  • Efficient Grid Compatibility:Supports standard grid connection configurations (e.g., Dyn11, YD5 with 120° phase shift) to match grid voltage and frequency requirements. Enables stable power inversion from DC (solar panels) to AC (grid), with conversion efficiency ≥98% to minimize energy loss.
  • Harmonic Suppression & Waveform Purity:Integrates low-loss core materials (e.g., oriented silicon steel) and foil winding technology to suppress 3rd harmonic distortion and maintain sine-wave output. Ensures compliance with grid power quality standards (e.g., IEEE 519) for reliable grid interconnection.
  • Adaptive Operation & Energy Savings:Features automatic daytime activation and nighttime shutdown to eliminate no-load losses. Suitable for off-grid/on-grid systems, with customizable capacity (5kVA–1000kVA) to match solar array scales.
  • Robust Environmental Adaptability:Constructed with weather-resistant enclosures (e.g., 304 stainless steel) for outdoor installations, resisting humidity, temperature fluctuations, and corrosion. Dry-type air cooling design ensures maintenance-free operation in harsh environments.
  • Customizable Design Flexibility:Supports voltage customization (input/output: 220V–1140V) and insulation classes (B/F/H) for diverse project needs. Compact structure fits limited space in solar power stations, with optional IP certifications for enhanced protection.

Technical data:

Conditions of Use. Working environment temperature: 15~+50℃

Operating ambient temperature:20—90%RH

Atmospheric pressure in the working environment:860 hpa---1060 hp2

Storage/transport temperature:20℃-- +55℃

Main technical features:

Rated capacity:5KVA—1000KVA

Input Voltage: Rated voltage 270V or 315V

Input current by actual voltage

Output voltage: Rated voltage: 380V or 400V

The output current is based on the actual voltage

Connection mode :dyn11

Efficiency :≤98.5%

Frequency: 50HZ/60HZ

Insulation resistance :25A less than 500MΩ

Induction withstand voltage :125HZ/800y/60

Insulation Chip Class :H (Temperature Resistance 180 °C)

Noise :≤30dB)

Temperature rise: ≤ allows for a temperature rise of 115k

Impedance Voltage Drop :≤4%

Structure: Forced air cooling, waiting for the temperature controller, according to customer requirements, reach a certain temperature, the fan will be automatically opened.

Degree of protection :IP00

Anti-interference mode: copper foil isolation shielding grounding:

Waveform Distortion No additional waveform distortion.

Electrical strength: Power frequency sinusoidal voltage 3000V, which lasts for one minute, without breakdown and flashover

Insulation resistance (input and output to ground) Test voltage at least 1000V DC insulation resistance greater than 1000MΩ

Overload capacity Twice the rated current for one minute.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!