• DS23B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS23B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS23B-550D/5000-63
DS23B-550D/4000-63
DS23B-420D/3150-63
DS23B-363D/5000-63
DS23B-363D/4000-63
DS23B-252D/5000-63
DS23B-252D/4000-63
DS23B-252D/3150-50
DS23B-252D/2500-50
DS23B-252D/2000-50
DS23B-126D/4000-50
DS23B-126D/3150-50
DS23B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS23B 126kV 145kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS23B
Product Detail

Product introduction

DS23B switch disconnector is a kind of outdoor HV electricity transmission equipment at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity nuns is changed. in addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is in the double-post horizontal telescopic structure, with the plug-type contact. Ater the opening, a horizontal insulating break will be formed. The product can be used as an disconnect switch at the 110kV to 550kV substation. The JW10 earthing switch can be attached at one or two sides, When two GW23B disconnect switches are combined into a fixed contact, half of the line for a switch can be cut of and the land coverage can be saved. 363kV and 550kV disconnect switch and earthing switch are equipped with the SRCJ8 motor actuator the single pole operation. Meanwhile, the tri-pole linkage can be achieved The 126kV and 252kv disconnect switches adopt SRCJ7 and SRCJ3 motor-based actuators to realize the tri-pole linkage. The earthing switch adopts CS11 and SRCS manual actuators to actualize tri-pole linkage.

This switch disconnector has passed the verification by the review procedure organized by China Machinery Industry Federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internally level of the same kinds of products."

DS23B switch disconnector comprises three single poles and actuator, Each pole consists of a movable side post and a fixed side post. The movable side post is made up of a base, post insulator, operating insulator, foldable conductive tube; while the static side post comprises a base, post insulator and static contact.

The actuator drives the operating insulator, and through the link lever, brings the foldable conducive tube to extend horizontally to plug the moving contact into or extract it out of the fixed contact so that the isolating switch can be opened or closed. After the opening, a horizontal insulating break will be formed.

Main characteristic

  • Superior conductance system: The conductive part made of Al-alloy of high conductance rate is characteristic of good conductance, high mechanical strength, light weight and strong corrosion resistance. The current will pass through the foldable area of the conductive arm via soft connection (without any movable contacts) to ensure reliable conductance, few maintenance, no examination, and long-term reliable operation.
  • State -of-art structure: The switch disconnector is in the single-arm, foldable and telescopic structure, The driving elements and balancing springs are sealed within the conductive tube to reduce their adverse effects on natural environment and render the appearance compact and simple. The drive base adopts a link lever, Compared with angular wheels, the product is simpler and easier to adjust
  • Simple and superior grounding switch363kV earthing switch is in the single-arm standing and openable structure, with the structurally simple plug-type contact. The conductive rod for grounding will move in two steps at the moments of opening and closing. At the moment of opening, the conductive rod will rotate vertically and rise up to the static contact, and then automatically plug itself into the star-shaped contact. By doing so, the contact will be made reliable and be able to sustain heavy short-circuit current.
  • Plug-type contact: The moving contact is the plug-type and has the self-cleaning ability. One end of the U-shaped finger of 126kV and 252kV fixed contact is fixed onto the contact base, forming a fixed connection and ensuring the reliable conduction; while the other end will produce contact pressure on the moving contact as a result of the influence of external spring and the own elastic force of the con-tact finger, and the gripping force will automatically increase when the short-circuit current passes through the contact. The contact spring is made of stainless steel and is equipped with insulating gasket. The spring will not corrupt nor shunt. The arc contact can be mounted onto the movable and fixed contacts to enable the disconnect switch to switch current, capacitive and inductive cur-rent by opening and closing bus line.
  •  Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters:

   

Order notice :

Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;

It can be decided whether a earthing switch should be attached to the switch disconnector;

It must be decided whether the upper bus line of the switch disconnector is soft or hard. Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the disconnect switch is arranged in cross-over or parallel form;

The actuator's model, motor's voltage, control voltage and the number of contacts for auxiliary switch.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!