• DS4C 252kV High voltage disconnect switch
DS4C 252kV High voltage disconnect switch
discuss personally
Model
DS4C-252/4000-50
DS4C-252/3150-50
DS4C-252/2500-50
DS4C-252/1600-50
Basic info
Brand ROCKWILL
Model NO. DS4C 252kV High voltage disconnect switch
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS4C
Product Detail

Product introduction:

GW4C Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs Is changed. In addition, It can be used lo exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product has two insulators with horizontal center breaks. It Is openable In the middle and accessible to the grounding switch on one side or two sides. The disconnect switch adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage,The earthing switch adopts CS14G manual operating mechanism to actual亿e tri-pole linkage

This product has been verified by the Chinese competent authority as having uniqueness in design and reaching intonational advanced level of similar products.

GW4C disconnect switch comprises three single poles and operating mechanism. Each single pole is made of a base, post insulator and conductive part revoting insulating posts are mounted at both sides of a long base. The conductive switch blade's contact arms are respectively fixed at the tops of the insulating posts.

When the Insulating post at one end of the actuator revolves to drive, and through the cross-over lever, brings the insulating post at the other end to rotate reversely by 90° to make the conductive switch blade circumgyrate. In this way, the isolating switch is opened and closed.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight targe radiation area and strong stance against corruption
  • The finger is made of pure copper and has a silver plating process. It has strong now capacity and long mechanical life. The stamping process ensures the reliability of contact and finger contact.
  • The contact finger pressure is prohormonal to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible wire).
  • The contact Is made of curved copper plate. In the opening and closing processes, there is a short trip of friction between the contact and the finger and the required operating force is small.
  • The rotating parts of the Switch Disconnector are designed to be free of any maintenance. The rotating base is designed into a closure structure which denies t沺access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden.
  •  Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

GW4C-parameters.png

 Order notice: 

Product model, rated voltage, rated current, Rated short-time withstand current and creepage distance must be specified at the goods-ordering time.

The disconnect switch offers several options of grounding (Left, right, both left and right).Unless otherwise specified, the goods supplied will be considered as providing the option of right grounding;

Note:

  • The methods of judging left end right grounding: hold out both arms and keep the arms in the same direction as the disconnect switch is opened. The earthing switch will be considered as left grounding non the left hand side, and right grounding if on the right hand side;
  • The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;
  • When the Switch Disconnector is used at the incoming and outgoing terminals of the substation in the double loop parallel overhead power transmission line, if the earthing switch requires the opening/dosing induction current then such requirement shall be specified. Besides, the parameters and the side at which the earthing switch Is set shall be defined. (Special notice: Not all earthing switches attached to the earthing switches and disconnect switches at the substation shall require the opening/closing Induction current)

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!