• DC 60-80-120-160-200-240KW EV Chargers
DC 60-80-120-160-200-240KW EV Chargers
$4700.00
Model
PCDC-YZ5-EU240/1k
PCDC-YZ5-EU240/1k
PCDC-YZ5-240/1k
PCDC-YZ5-EU200/1k
PCDC-YZ5-EU200/1k
PCDC-YZ5-200/1k
PCDC-YZ5-EU160/1k
PCDC-YZ5-EU160/1k
PCDC-YZ5-160/1k
PCDC-YZ5-EU120/1kk
PCDC-YZ5-EU120/1k
PCDC-YZ5-120/1k
PCDC-YZ4-EU80/1k
PCDC-YZ4-EU80/1k
PCDC-YZ4-80/1k
PCDC-YZ4-EU60/1k
PCDC-YZ4-EU60/1k
PCDC-YZ4-60/1k
Basic info
Brand Pingalax
Model NO. DC 60-80-120-160-200-240KW EV Chargers
Rated Output Rating 60kW
Output Voltage DC 200-1000V
Max Output Current 200A
Power Conversion Efficiency ≥95%
Connector Options GBT+GBT
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

60120KW1.png

60120KW2.png

What is OCPP Communication?

OCPP (Open Charge Point Protocol) is an open communication protocol mainly used for communication between electric vehicle charging stations (also known as charging piles or charging points) and central management systems. OCPP aims to achieve interoperability of charging infrastructure, enabling charging equipment produced by different manufacturers to communicate effectively with different central management systems.

Client-server model:

  • Charge Point: As the client, it is responsible for communicating with the central management system.

  • Central System: As the server, it receives information from the charging station and issues instructions.

Know your supplier
Pingalax
Main Categories
New energy
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
3 years
Workplace
6000m²
占位
占位
Related Products
Related Knowledges
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
What tests need to be done on voltage transformers?
What tests need to be done on voltage transformers?
Practical Experience Sharing from an Electrical Engineer in the FieldBy Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early involvement in substation commissioning and equipment inspection, to now managing the maintenance and fault analysis of entire power systems, one of the most frequently encountered devices in my work has been the voltage transformer (VT / PT).Recently, a friend who's just starting out ask
Oliver Watts
07/03/2025
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr