• DC 30/40KW EV Chargers
DC 30/40KW EV Chargers
$2258.00
Model
PCDC-WZ2-EU40/1k
PCDC-WZ2-EU40/1k
PCDC-WZ2-EU40/1k
PCDC-WZ2-EU40/1k
PCDC-WZ2-40/1k
PCDC-WZ2-40/1k
PCDC-WZ2-40/1k
PCDC-WZ2-40/1k
PCDC-WZ2-EU30/1k
PCDC-WZ2-EU30/1k
PCDC-WZ2-EU30/1k
PCDC-WZ2-EU30/1k
PCDC-WZ2-30/1k
PCDC-WZ2-30/1k
PCDC-WZ2-30/1k
PCDC-WZ2-30/1k
Basic info
Brand Pingalax
Model NO. DC 30/40KW EV Chargers
Mounting type Bracket-mounted
Rated Output Rating 30KW
Output Voltage DC 200-1000V
Max Output Current 100A
Connector Options GBT
Cable Length 5m
Methods of Communication Bluetooth,WIFI,RJ45
Series DC EV Chargers
Product Detail

3040KW1.png

3040KW2.png

How is the DC car charger protected from leakage?

Basic principle of leakage protection:

  • Leakage detection: Detect whether there is current flowing into the ground or other unintended paths other than the normal path.Automatic power off: Once a leakage is detected, the system will automatically cut off the power supply to prevent accidents.

Main technical means of leakage protection

Residual current device (RCD/RCCB):

  • Definition: A residual current device (RCD) or residual current circuit breaker (RCCB) is a device used to detect leakage current and cut off the power supply when leakage is detected.

  • Working principle: The residual current device judges whether there is leakage by detecting whether the current flowing in and out of the circuit is balanced. When an unbalanced current (i.e., leakage current) is detected, the residual current device will quickly cut off the power supply.

Current transformer (CT):

  • Definition: A current transformer is a device used to detect changes in current in a circuit.

  • Working principle: In a DC car charger, a current transformer can detect changes in current in the charging circuit. If abnormal current (such as leakage current) is detected, the system will trigger a protection action.

Ground fault protection (GFCI):

  • Definition: A ground fault circuit interrupter (GFCI) is a device used to detect and cut off ground fault current.

  • Working principle: The GFCI compares the input current and output current in the charging circuit. When the two are inconsistent, it is considered that there is a leakage phenomenon and the power supply is immediately cut off.

Know your supplier
Pingalax
Main Categories
New energy
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
3 years
Workplace
6000m²
占位
占位
Related Products
Related Knowledges
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Impact Analysis of Voltage Transformer Installation on Line Side vs. Load Side of Power Inlet Circuit Breaker for (ATS)
Automatic backup switching (ABTS) devices are core components ensuring the safe, reliable, and stable operation of factory power grids. Their startup logic strictly follows the dual criteria of "loss of voltage in the working power supply + no - current detection", effectively avoiding misjudgments caused by secondary disconnection of voltage transformers (VTs) or maloperations of ABTS due to secondary circuit faults of current transformers (CTs). The activation condition requires both "no volta
James
07/03/2025
What tests need to be done on voltage transformers?
What tests need to be done on voltage transformers?
Practical Experience Sharing from an Electrical Engineer in the FieldBy Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early involvement in substation commissioning and equipment inspection, to now managing the maintenance and fault analysis of entire power systems, one of the most frequently encountered devices in my work has been the voltage transformer (VT / PT).Recently, a friend who's just starting out ask
Oliver Watts
07/03/2025
What are the development trends of voltage transformers?
What are the development trends of voltage transformers?
By Echo, 12 Years in the Electrical IndustryHi everyone, I'm Echo, and I've been working in the electrical industry for 12 years.From early involvement in commissioning and maintenance of distribution rooms to later participation in electrical system design and equipment selection for large-scale projects, I’ve witnessed how voltage transformers have evolved — from traditional analog devices to intelligent, digital components.The other day, a new colleague from a power company asked
Echo
07/02/2025
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
Design of Electromagnetic Compatibility Performance for Electronic Voltage Transformers
With the rapid development of power systems, electronic voltage transformers (EVTs), as key measurement devices in power systems, their performance stability and reliability are crucial for the safe and stable operation of power systems. The electromagnetic compatibility (EMC) performance, as one of the core indicators of EVTs, is directly related to the ability of the device to work normally in complex electromagnetic environments and whether it will cause electromagnetic interference to other
Dyson
07/02/2025
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
Case Analysis of Abnormal Secondary Circuits in Voltage Transformers
1. Fault SituationIn September 2023, as a front - line fault maintenance worker, I detected abnormal voltage on the 10kV Section I bus of a substation during monitoring duty and informed the operation and maintenance team. The monitoring system showed: U0 = 0 kV, Ua = 6.06 kV, Ub = 5.93 kV, Uc = 6.05 kV, Uab = 10.05 kV, Ubc = 5.94 kVMy team and I rushed to the site. We suspected the secondary air circuit breaker of the 10kV Section I bus voltage transformer was closed and found the U - phase fus
Felix Spark
07/02/2025
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
What are the causes of failure of ferromagnetic voltage transformers in new energy power stations?
By Felix, 15 Years in the Electrical IndustryHi everyone, I'm Felix, and I've been working in the electrical industry for 15 years.From early involvement in traditional substation commissioning and maintenance to now managing electrical system operations for multiple photovoltaic and wind power projects, one of the most frequently encountered devices I deal with is the Electromagnetic Voltage Transformer (PT).The other day, a shift operator at a new energy plant asked me:“We have an electr