• 72.5kV High - voltage Vacuum Circuit Breaker
72.5kV High - voltage Vacuum Circuit Breaker
discuss personally
Model
LW36-72.5
Basic info
Brand ROCKWILL
Model NO. 72.5kV High - voltage Vacuum Circuit Breaker
Rated voltage 72.5kV
Rated normal current 3150A
Rated frequency 50/60Hz
Series ZW36-72.5
Product Detail

Product introduction:

  • 72.5kV High - voltage Vacuum Circuit Breaker is a crucial electrical device. It uses vacuum as the arc - extinguishing and insulating medium, boasting high reliability and excellent performance.

  • This breaker can quickly and effectively cut off load current and short - circuit current, protecting the power system. It features a high - current breaking capacity and a long electrical life.

  • With a compact structure, it is suitable for both indoor and outdoor applications in 72.5kV power systems. It complies with relevant international and national standards, ensuring stable and safe operation in power distribution networks.

Main characteristic:

  • Excellent arc - extinguishing and insulation: Using vacuum as the arc - extinguishing and insulation medium, it has strong arc - extinguishing ability and stable and reliable insulation performance. It can effectively prevent arc reignition and other problems, ensuring the safe operation of the power system.

  • Powerful breaking capacity: It can quickly and efficiently cut off load current and short - circuit current. It has high rated current and short - circuit breaking current parameters. For example, the rated current can reach 3150A, and the rated short - circuit breaking current can reach 40kA, which can meet the current breaking requirements of different working conditions in the power system.

  • Long mechanical and electrical life: The mechanical life can reach 20,000 times, and the electrical life can reach 30 times. It is not easy to be damaged by frequent operations, reducing the frequency of equipment replacement and maintenance, and lowering the operation and maintenance costs.

  • Good environmental adaptability: The operating ambient temperature range is - 40~55℃, enabling it to work stably in various climatic conditions. It can operate normally in areas with an altitude of no more than 5000m, is suitable for pollution class Ⅲ environments, has an aseismatic class of AG5, and a wind speed resistance of 34m/s, adapting to different geographical and environmental conditions.

  • Reasonable structural design: It has a compact structure, occupies a small space, and is easy to install and arrange. There are multiple structural forms available (such as the common porcelain column type and handcart type), which is convenient for integration with different power systems and equipment.

  • Compliance with standards and specifications: It is manufactured in strict accordance with relevant international and national standards, ensuring stable product quality and performance, and enabling reliable operation in the power system.

Main technical parameters:

Instructions on placing orders :  

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store motor and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!