• 600 W ~ 630 W High-power N-type TOPCON bifacial modules
  • 600 W ~ 630 W High-power N-type TOPCON bifacial modules
600 W ~ 630 W High-power N-type TOPCON bifacial modules
discuss personally
Model
WN6.2-66TB-630
WN6.2-66TB-600
Basic info
Brand RW Energy
Model NO. 600 W ~ 630 W High-power N-type TOPCON bifacial modules
Power Bifaciality 80%
Max. System Voltage 1500V (IEC)
Max. Series Fuse Rating 35 A
Module Fire Performance CLASS C
Max. power of the module 630W
Max. efficiency of Module 22.2%
Series N-type Bifacial TOPCon Technology
Product Detail

Features

  • Module power up to 630 W Module efficiency up to 23.3 %.

  • Up to 85% Power Bifaciality, more power from the back side.

  • Excellent anti-LeTID & anti-PID performance. Low power degradation, high energy yield.

  • Lower temperature coefficient (Pmax): -0.29%/°C, increases energy yield in hot climate.

  • Lower LCOE & system cost.

Standard

  • Tested up to ice ball of 35 mm diameter according to IEC 61215 standard.

  • Minimizes micro-crack impacts.

  • Heavy snow load up to 5400 Pa, wind load up to 2400 Pa*.

Engineering drawing(mm)

image.png

CS6.2-66TB-610 / I-V gurves

image.png

Electrical date/STC*

企业微信截图_17300963096490.png

Electrical date/NMOT*

image.png

Electrical date

image.png

 Charactheristics date

image.png

Temperature characteristics

image.png

What is bifacial gain in PV modules?

Definition:

The maximum power bifaciality ratio refers to the ratio of the maximum power that can be generated on the back side of a bifacial photovoltaic module to the maximum power on the front side under standard test conditions (Standard Test Conditions, STC). It is a percentage value used to quantify the contribution degree of the power generation capacity on the back side of the bifacial module relative to that on the front side.

Calculation Formula:

The maximum power bifaciality ratio can be expressed by the following formula:

Maximum Power Bifaciality Ratio (%) = (Maximum Power on the Back Side / Maximum Power on the Front Side) × 100%

Here, "Maximum Power on the Back Side" refers to the maximum power that can be generated on the back side of the bifacial photovoltaic module under standard test conditions; "Maximum Power on the Front Side" refers to the maximum power that can be generated on the front side under the same conditions.


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!