• 40.5kV HV Gas circuit breaker
40.5kV HV Gas circuit breaker
discuss personally
Model
LW36-40.5(W)/T4000-50
LW36-40.5(W)/T4000-40
LW36-40.5(W)/T3150-40
LW36-40.5(W)/T2500-40
LW36-40.5(W)/T2500-31.5H
Basic info
Brand Wone
Model NO. 40.5kV HV Gas circuit breaker
Rated voltage 40.5kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 50kA
Series LW36-40.5
Product Detail

Product introduction

LW36-40.5 outdoor self-energy HV AC SF6 circuit breaker is an outdoor three-phase HV AC equipment used in electricity grids with altitudes of no more than 3000m, environment temperatures of no less than -40℃, local pollution classes of no higher than Class IV, and AC 50Hz/60Hz with maximum voltage of 40.5kV, it is suitable for the control and protection of HV supply and transformation lines in power station, converting stations, and industrial and mining enterprises. it can also be used as connection circuit breaker.

Main characteristic

LW36-40.5 self-energy HV SF6 circuit breaker is equipped with advanced hot-expansion plus auxiliary pressure gas self-energy arc extinguishing technology and matched with new-type spring actuating mechanism, it has features such as long electrical endurance, small operating power, high electrical and mechanical reliability, high technical parameters, and moderate price. Lt’s main performance features are as follows:

1、High rated technical parameters: rated current 2500A/4000A and rated short circuit breaking current 31.5KA/40KA/50KA.suitable for the opening and closing of large-capacity electricity grids.

2、High electrical reliability

No-load line charging breaking ability and no-load cable charging breaking ability 50/60Hz dual-frequency C2,back-to-back capacitor bank breaking ability 50/60Hz dual-frequency C2, no re-breakdown;

Strong external insulation ability;, suitable for regions with 3000m of altitude or Class lV pollution.

3、High reliability of operating mechanism:

Mechanical endurance: separating and closing for 10000 times without replacing parts; can meet the user' s requirement of continuous running and little maintenance.

New type spring actuating mechanism has few components parts; overall high-strength cast aluminum frame and brake separating and closing spring; and centralized arrangement is adopted for the buffer, compact structure, reliable operation, low noise, and convenient maintenance; suitable for frequent operations.

4、Al exposed parts are made of stainless steel materials or hot-galvanized on the surface for high corrosion resistance.

5、Reliable sealing structure ensures the product annual leakage rates≤0.5%.

6、Four internally attached current mutual inductors for every phase can be installed on the circuit breaker. Microcrystal alloy and high permeability material are adopted for internally attached current mutual inductors. The accuracy of 200A and above current mutual inductors can reach up to Level 0.2 or 0.2S. Reliable electrical screening design is adopted for the cable coils of internally attached current mutual inductors to improve the electric field distribution of the mutual inductors and promote the internal insulation of the product. it can withstand 120kv and 5min working frequency withstand voltage test and the internal insulation is not interfered by the short circuit breaking working conditions, which makes it safe and reliable.

Main technical parameters

1732519731006.png

Order notice 

Model and format of the circuit breaker.

Rated electrical parameters (voltage, current, breaking current, etc.);

Environmental conditions for using (environment temperature, altitude, and environment pollution level);

Rated control circuit electrical parameters (power-storage electromotor rated volage and brake separating and closing cable coil rated voltage);

Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

The wire connecting direction of the primary upper terminal.

 


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
A Novel Detection Method for Stuck Faults in Load Switches
A Novel Detection Method for Stuck Faults in Load Switches
In recent years, as distribution automation advances, load switches see wider use in distribution lines. Yet, mechanical - failure - induced accidents are on the rise, burdening line operation and maintenance.Poor mechanical performance is the main cause of switch faults. Many scholars study large - scale switchgear operation, using methods like coil current detection, vibration signal analysis, switch travel testing, ultrasonic flaw detection, and infrared thermometry. Motor - current - based s
Oliver Watts
06/30/2025
What You Need to Know About Load Switch Malfunctions
What You Need to Know About Load Switch Malfunctions
Hey there, I’m Blue — been working as an electrical engineer for more than 20 years now.I’ve spent most of my career designing circuit breakers, managing transformers, and helping power companies solve all sorts of electrical system challenges.Today, a friend from Southeast Asia asked me:"What are the common faults of load switches?"Great question! So let’s break it down in simple terms — no fancy jargon, just real-world stuff you might actually see on the job or during maintenance.First, What E
Master Electrician
06/30/2025
What tests need to be conducted for load switches?
What tests need to be conducted for load switches?
As a technician with years of on-site experience in power testing, I understand the importance and complexity of load switch testing. Below, I combine practical work experience to elaborate on the full process of load switch testing, from testing items and methods to equipment and procedural specifications.I. Routine Electrical Performance Testing(1) Loop Resistance TestLoop resistance is a core indicator for evaluating a load switch's conductivity. I strictly follow GB/T 3804 and GB 1984 standa
Oliver Watts
06/28/2025
What are the common faults of load switches?
What are the common faults of load switches?
As an on-site maintenance technician, I frequently deal with electrical, mechanical, and insulation faults in load switches. The following outlines fault manifestations, causes, and solutions:I. Electrical Fault Handling(1) Contact HeatingContact heating is mainly caused by poor contact, insufficient pressure, or three-phase asynchrony. When the contact resistance exceeds 1.5 times the initial value, the temperature rise will exceed the standard in a 40℃ environment. For example, the FW4-10 swit
Felix Spark
06/28/2025
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
Short-Circuit Fault Analysis of 10kV Puffer-Type Load Switch
1. Fault OverviewIn June 2013, a fault occurred in a high - voltage switchgear in operation in a certain urban area, causing a 10kV line to trip. On - site investigation revealed that the faulty switchgear was a pneumatic ring - network high - voltage load switchgear (HXGN2 - 10 type), and the fault characteristic was athree - phase arc short circuit. After isolating the fault and restoring power supply to users, it should be noted that the same type of switchgear in this area, which was put int
Felix Spark
06/28/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!