• 1kW / 1.036 KWh portable power station
  • 1kW / 1.036 KWh portable power station
1kW / 1.036 KWh portable power station
discuss personally
Model
WN-1000
Basic info
Brand Wone
Model NO. 1kW / 1.036 kWh portable power station
输出功率 1000W
Energy capacity 1036Wh
Series Portable power station
Product Detail

Description:

This 1kW / 1.036 kWh portable power station can support up to 12 devices simultaneously, is easy to carry (11kg), and ideal for outdoor activities as well as emergency power supply for homes. This is a lifestyle change-maker and the dream device for adventurers.

Feature:

  • 3- Level Brightness.

  • SOS Function.

  • Equipped with 2 Wireless Charging Pads.

  • Capable to Charge 12 Devices Simultaneously.

  • Big Capacity in Small Box.

Basic parameters:

image.png

Electrical Parameters:

image.png

How are portable charging stations overcharged protected?

Voltage Detection:

  • Function: The Battery Management System (BMS) continuously monitors the voltage of each battery cell.

  • Principle: When the voltage of a battery cell reaches or approaches the preset upper limit (for example, the upper limit of a lithium-ion battery is usually 4.2V), the BMS will trigger overcharge protection.

Current Detection:

  • Function: The BMS monitors the charging current.

  • Principle: If the charging current exceeds the preset safety threshold, the BMS will reduce the charging current or completely cut off the charging circuit.

Temperature Detection:

  • Function: The BMS monitors the temperature of the battery.

  • Principle: If the battery temperature exceeds the preset safety threshold (for example, 60°C), the BMS will reduce the charging current or completely cut off the charging circuit to prevent dangers caused by overheating.

Logic Control:

  • Function: The BMS makes logical judgments based on the data of voltage, current, and temperature to decide whether to activate overcharge protection.

  • Principle: The microprocessor built into the BMS will judge whether the battery is in an overcharged state according to the preset algorithms and thresholds. If overcharge conditions are detected, the BMS will execute corresponding protection measures.

Protection Measures:

  • Cutting off the Charging Circuit: The BMS cuts off the charging circuit by controlling the charging relay or MOSFET (Metal Oxide Semiconductor Field Effect Transistor) to prevent the current from continuing to flow into the battery.Reducing the Charging Current: In some cases, the BMS may first reduce the charging current to observe the changes in the battery state. If the battery voltage still rises, then the charging circuit will be completely cut off.

  • Alarm Notification: The BMS can issue an alarm through the display screen or indicator light to remind the user that the battery has reached a full charge state and the charger needs to be disconnected.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry
Download