• 3.6kV-24kVThe Indoor metal-clad withdrawable switchgear
3.6kV-24kVThe Indoor metal-clad withdrawable switchgear
discuss personally
Model
KYN-12/2000-15
KYN-24/4000-40
KYN-7.2/1600-25
KYN-3.6/1250-25
Basic info
Brand ROCKWILL
Model NO. 3.6KV-24KVThe Indoor metal-clad withdrawable switchgea
Rated voltage 12kV
Series KYN
Product Detail

Description:

The Indoor metal-clad withdrawable switchgear(hereinafter short as switchgear) is a complete power distribution device for 3.6~40.5kV, 3-phase AC 50/60Hz,single-bus and single-bus sectionalized system.

It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc. so as to control, protect and monitor the system. The medium voltage switchgear meets IEC298,GB3906-91. In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc. It is truly a power distribution device with good performance.

In order to meet the requirements for wall mounting and front-end maintenance, the medium voltage switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

  • Enclosures able to withstand internal arcing.

  • 3 or 4 sides internal arc protection IAC: A-FL and A-FLR. Internal arc withstand: 12.5 kA 1s, 16 kA 1s and 20 kA 1s.

  • Mechanical and electrical interlocks, to prevent incorrect operations.

  • 100% factory-tested without the need for further tests on site.

  • Easy upgraded to meet your need and adapted to the extension of your installations.

  • Integration in factory-built outdoor substations for which the SM6 is particularly well designed.

  • Intelligent, connectable components like SC110 and TH110 provide continuous information about the health of your electrical installations, enabling asset management optimization through preventive maintenance.

Technical parameters:

image.png

Product detail:


企业微信截图_17211091605892.png

企业微信截图_17211092656460.png

企业微信截图_17211092834133.png

What is the working principle of the indoor metal armored pull-out  switchgear?

Circuit Control and Protection:

  • Circuit Control:

  • Circuit breakers control the opening and closing of circuits. The working principle of circuit breakers is based on electromagnetic induction and thermal effects. During normal operation, current flows through the contacts of the circuit breaker, which remain closed. When an overload condition occurs, and the current exceeds the rated current of the circuit breaker, the internal thermal trip mechanism will open the contacts due to the heat generated by the current, thereby interrupting the circuit.

  • In the event of a short circuit, the high short-circuit current will cause the internal electromagnetic trip mechanism to act instantly, quickly opening the contacts and protecting electrical equipment and lines from damage caused by excessive current.

Protection Devices:

  • Other protective devices, such as overcurrent relays and ground fault protection relays, are also equipped. These protection devices continuously monitor parameters such as current and voltage in the circuit. If any abnormality is detected, they send a trip signal to the circuit breaker, ensuring the safety of the circuit.

Power Distribution:

  • Power is introduced into the switchgear's busbar compartment via busbars. The busbars distribute the power to the circuit breakers in each branch. The circuit breakers then transmit the power to different load circuits, enabling the control of power supply to multiple loads. For example, in a building's power distribution system, medium-voltage power from a substation first enters the busbar of the switchgear and is then distributed to the distribution panels on each floor through circuit breakers, providing power to lighting, outlets, and other equipment on those floors.

Interlocking Functions:

  • To ensure operational safety, the switchgear is equipped with various interlocking mechanisms. For example:

  • The trolley can only be moved from the service position to the test or maintenance position when the circuit breaker is in the open (off) state.

  • There is an interlock between the grounding switch and the circuit breaker. When the grounding switch is in the closed (on) position, the circuit breaker cannot be closed, and vice versa.

  • These interlocking devices effectively prevent operator errors and avoid dangerous operations such as switching under load or closing the grounding switch while the circuit is energized.



Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!