• 250kVA-2500 kVA Compact substation(Prefabricated Substation)
  • 250kVA-2500 kVA Compact substation(Prefabricated Substation)
250kVA-2500 kVA Compact substation(Prefabricated Substation)
discuss personally
Model
YBM-800
YBM-630
YBM-250
YBM-1250
Basic info
Brand ROCKWILL
Model NO. 1250 kVA Compact substation
Rated voltage 35kV
Capacity 800kVA
Series Compact Substation
Product Detail

Product overview:

  • 250- 2500kVA Compact substation can replace the traditional indoor substation, can meet the user's electric energy measurement, reactive power compensation, high and low voltage.

  • schemes and other configuration requirements, representing the development direction of small and medium-sized substations.

  •  Rated AC frequency 50Hz/60HZ, maximum operating voltage to 35KV, maximum operating current to 5000A.

  • This product is suitable for industrial and mining enterprises, wharfs, public places, high-rise buildings and residential areas.

  • Products are mainly exported to Asia, Africa and other regions, providing OEM/ODM services.

  • Standard: IEC60067 GB 17467-2010, etc.

Product advantages:
Leading technology:

  • Fully enclosed and insulated structure, safe and reliable operation.

  • Easy to operate, maintenance-free, low equipment cost.

The shell:

  • The casing has the characteristics of firm, heat insulation and ventilation, stable performance (anti-corrosion, dustproof, waterproof) and beautiful appearance.

  • Various choice of shell materials, such as steel plate, composite plate, stainless steel plate, cement plate and other protection grade (IP67) .

Functional units:

  • Divided into high voltage room, low voltage room, transformer room three independent areas.

  • XGN15, HXGN17 or SF6 switchgear is selected for high pressure chamber.

  • The low-voltage side adopts panel or cabinet mounted structure to form the power supply scheme required by users, which can meet the power distribution, lighting distribution,

    reactive power compensation, energy metering and other functions. The main switch generally uses universal circuit breaker, but also can choose intelligent circuit breaker, flexible installation, easy operation.

  • The transformer can be fully sealed oil-immersed transformer or dry transformer.

Busbar system:

  • Three-phase four-wire system or three-phase five-wire system.

  •  High quality three phase tinned bus copper bar, high mechanical strength, good heat dissipation..

Product parameters:

Conditions of use:

  •  The ambient air temperature shall not exceed a maximum of 45 ° C and a minimum of -45 ° C.

  •  The altitude is not more than 1000m, and can reach 4000m if special custom transformers and low-voltage components are used.

  •  The vertical inclination is not more than 5°, and there is no violent vibration and no impact.

  •  Air humidity not greater than 90% (+25℃).

  •  No conductive dust, no explosion hazard, no corrosive metal and electrical components in the gas place.

  • Outdoor wind speed should not exceed 35m/s.

  •  The above normal operating environment conditions, customers can be customized with WONE you Electric to solve.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  • Equipment layout drawing, combination drawing, floor plan drawing.

  • Model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Equipment shell material and color.

  • Other special requirements can be negotiated with the manufacturer.

  • Welcome customers to visit the factory, provide OEM/ODM protection level.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th