• 12kV 24kV air insulated Ring Main Unit (RMU)
12kV 24kV air insulated Ring Main Unit (RMU)
discuss personally
Model
SM66-24
Basic info
Brand ROCKWILL
Model NO. 12kV 24kV air insulated Ring Main Unit (RMU)
Rated voltage 24kV
Rated normal current 630/800A
Rated frequency 50/60Hz
1min Power frequency withstand voltage 60kV
Series SM66
Product Detail

Description :

SM66-12/24 unit type SF6 RMU with SF6 load switch as main switch, for whole  cabinet is suitable for electric distribution automation and compact also expandable  metal close switchgear. It characters in its simple structure, flexible operation, reliable  interlocking and convenient installation etc., which can provide the satisfactory  technical projects both for different application occasions and users. With the  adoption of sensor technology and the protection relay up to date, plus the advanced  technology and flexible assembly project, SM66-12/24 unit type SF6 RMU can  completely meet the requirement of continuously variable market. It can take  self-produced RLS-12/24 load break switch; also according to user's demand can be  assembled with the internationally top-ranking RCB series vacuum circuit breaker  with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit  breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our  VSC-12/24 type vacuum circuit breaker with permanent magnetic mechanism.  Operational methods for the main switch inside ring main unit can be either manual or  electric power driven. And It can meet the requirement of "Four Controls" when  matched with FTU and RTU.

Technical feature:

  • Good Insulation Performance;

  • Strong Arc Extinguishing Ability;

  • High Safety;

  • Flexible and Reliable Operation;

  • Compact Structure and Modular Design;

  • High Degree of Intelligence.

Technology parameters:

12kV 24kV air insulated Ring Main Unit (RMU).png

Note: For short circuit breaking and peak current is based on Fuse plus combination.

Q:What is the purpose of a ring main unit RMU?

A:A ring main unit (RMU) is used to distribute electrical power in a medium - voltage distribution network. It allows for sectionalizing the network, isolating faults, and enabling power transfer between different sections of the ring - shaped power network, ensuring reliable power supply.

Q:What does the RMU stand for?

A:RMU stands for Ring Main Unit. It is a type of electrical switchgear used in medium-voltage electrical distribution systems, typically for distributing power in a ring circuit configuration.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Documents
Restricted.
Air insulated Ring Main Unit (RMU)
Manual English
Consulting
Related Products
Related Knowledges
Development of an Outdoor Integrated Low - Voltage Current Transformer
Development of an Outdoor Integrated Low - Voltage Current Transformer
In power grid construction, line losses reflect planning, design, and operation management. They’re key for evaluating power systems. For refined low - voltage transformer area line loss management, accurate line loss counting is critical. So, solidifying basic data, ensuring data accuracy, and proper original data collection matter for analysis. We must also optimize factors affecting collection accuracy, make preventive measures, and boost refined line loss management.1 Current Status of
Dyson
07/05/2025
What might be the future development trends of outdoor current transformers?
What might be the future development trends of outdoor current transformers?
I'm Echo, a 12-Year Veteran in the CT Industry, Talking About What's Coming NextHi everyone, I'm Echo, and I've been working in the current transformer (CT) industry for 12 years.From learning wiring and equipment debugging with my mentor to now leading a team tackling complex on-site issues, I've witnessed many technological advancements and industry changes. Especially with outdoor current transformers, there have been significant developments, but also much room for improvement.A few days ago
Echo
07/05/2025
Ratio Trial Verification Method for Current Transformers
Ratio Trial Verification Method for Current Transformers
Fellow electric power calibration workers, you must have encountered this situation: The nameplate of an outdoor current transformer has been tormented by wind, sun, rain, and freezing, to the point where the transformation ratio is indistinguishable! Don't panic, we have a solution - use a current transformer calibrator and through the “transformation ratio trial calibration method”, we can figure out the actual transformation ratio and errors clearly. Here, taking the SHGQ - DC typ
Oliver Watts
07/05/2025
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
Why Does the Secondary Insulation of Outdoor Current Transformers Drop?
I'm Felix, a 15-Year Veteran in the CT Industry, Sharing What You Need to Watch Out ForHi everyone, I'm Felix, and I've been working with current transformers (CTs) for over 15 years. Today, let’s talk about why the secondary insulation of outdoor CTs sometimes drops, and what you can do to prevent it.Common Causes:1. Moisture Ingress — Poor Sealing is the Biggest Problem!Outdoor CTs are constantly exposed to wind and rain. If the sealing isn't tight enough, moisture can get inside a
Felix Spark
07/05/2025
What tests need to be conducted on current transformers?
What tests need to be conducted on current transformers?
By Oliver, 8 Years in the Electrical IndustryHi everyone, I'm Oliver, and I've been working in the electrical industry for 8 years.From early days doing substation equipment commissioning to now managing protection and metering configurations for entire distribution systems, one of the most frequently used devices in my work has been the Current Transformer (CT).Recently, a friend who's just starting out asked me:“How do you test current transformers? Is there a simple and effective way to
Oliver Watts
07/04/2025
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
What should be noted when choosing a current transformer for a 10kV station transformer circuit?
Practical Experience Sharing from an Electrical Engineer in the FieldBy James, 10 Years in the Electrical IndustryHi everyone, I'm James, and I've been working in the electrical industry for 10 years.From early involvement in substation design and equipment selection, to later taking charge of relay protection and automation system commissioning for entire projects, one of the most frequently used devices in my work has been the current transformer (CT).Recently, a friend who's just starting out
James
07/04/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!