• Low-Loss Three-Phase Photovoltaic Isolation Transformer
Low-Loss Three-Phase Photovoltaic Isolation Transformer
discuss personally
Model
SG-1250kVA
SG-300kVA
Basic info
Brand ROCKWILL
Model NO. Low-Loss Three-Phase Photovoltaic Isolation Transformer
Rated frequency 50/60Hz
Rated capacity 1250kVA
Phases Three-phase
Series SGG
Product Detail

Product Overview:

For many years, our company has specialized in manufacturing SD/SG(YSD) series single-phase and three-phase dry-type transformers dedicated to mechanical equipment, with capacities ranging from 1KVA to 3000KVA. Developed by referencing the latest similar products from Siemens, our SG series three-phase dry-type transformers not only provide voltage transformation in the power grid but also isolate third harmonics from the grid to equipment, reducing heat generation in machines and extending the service life of insulating materials. They are particularly suitable for imported equipment (380V input → 220V output, 380V input → any voltage output, 220V input → any voltage output) with specifications from 1KVA to 3000KVA.

Our SG and DG series dry-type isolation transformers are widely applicable to various power supply scenarios with AC 50-60HZ and input/output voltages not exceeding 3000V. All parameters, including input/output voltage levels, connection groups, tap positions, winding capacity distribution, secondary winding configurations, and whether a casing is required, are meticulously designed and manufactured according to user requirements.

Material Configuration Description of Transformer:

Transformers serve as the main components of various power supplies and electrical equipment. Isolation transformers consist of cylindrical windings and laminated cores, where the core is stacked with brand-new high-quality high-silicon silicon steel sheets using fully mitered joints. Our company employs advanced manufacturing processes, including imported Max high-speed automatic winding machines and a full set of vacuum pressure impregnation (VPI) equipment. The windings are formed using the skeletonless full-series winding method, and the transformers undergo vacuum impregnation to achieve insulation classes of F (155℃) or H (180℃).The input and output voltages of the transformer can be designed according to customer requirements, available in various specifications such as single-phase, three-phase, or multiple-way input/output configurations.

  •  Core:Made of brand-new high-quality high-silicon silicon steel sheets, mainly with materials of 0.35mm thick H18, H14, H12, and Z11 high-quality silicon steel sheets. We select the most suitable material based on customer requirements and usage conditions to optimize the transformer's performance design. (Conventional material: brand-new high-quality silicon steel sheets).

  • Wire:Using PEW, UEW, EIW, SEIW, FEAI enameled wires and glass fiber-covered wires, with temperature resistance grades of F (155℃), H (180℃), HC (200℃), and C (220℃). (Conventional temperature resistance grade: H grade, 180℃).

  • Insulating Materials:Adopting high-temperature resistant insulating paper as the insulating material, which has multiple properties of high-temperature insulation, flame retardancy, and moisture resistance.

  •  Insulating Material Terminal Blocks

  • For low-power applications: Using terminal blocks, which feature a beautiful appearance and excellent voltage resistance, temperature resistance, and flame retardant properties.

  • For high-power applications: Using high-quality copper busbars.

  •  Iron Feet:Mainly made of CNC bent cold-rolled steel plates, with environmentally friendly electroplating options such as multicolor plating (golden yellow), blue zinc (silver white), white zinc (ivory white), and surface anodizing (black).

Technical data:

Product Operating Conditions:

  • Applicable altitude: ≤ 5000m

  • Ambient temperature: -15℃~+45℃

  • Relative humidity: ≤ 90%

  • The installation site shall be free of gases, vapors, chemical deposits, dirt, conductive dust that seriously affect the insulation strength of the transformer, and free of other explosive, flammable, and corrosive substances.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Installation and Commissioning of 10kV Dry-Type Transformers
Installation and Commissioning of 10kV Dry-Type Transformers
By James, 10 Years of Electrical Equipment Maintenance ExperienceHi everyone, I’m James, and I’ve been working in electrical equipment fault repair for 10 years.Over the past decade, I’ve worked in factories, substations, and distribution rooms of all sizes, involved in the installation, commissioning, maintenance, and troubleshooting of dry-type transformers. Dry-type transformers are among the most common electrical devices we deal with on a daily basis.Today, a new colleague
James
07/01/2025
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
What are the reasons for low insulation at the low-voltage side of a dry-type transformer?
Hi everyone, I’m Felix, and I’ve been working in electrical equipment fault repair for 15 years.Over these years, I’ve traveled across factories, substations, and distribution rooms all over the country, troubleshooting and repairing all kinds of electrical equipment. Dry-type transformers are among the most common devices we deal with.Today, a friend asked me:“What does it mean when the low-voltage side of a dry-type transformer has low insulation resistance?”Great
Felix Spark
07/01/2025
What tests are required for dry-type transformers?
What tests are required for dry-type transformers?
1 Pre - commissioning InspectionAs a front - line tester, before formally commissioning a dry - type transformer, I need to carry out a comprehensive and systematic inspection. First, I conduct a visual inspection of the transformer body and its accessories, carefully checking for mechanical damage or deformation. Then, I check whether the leads of the high - and low - voltage windings are firmly connected and whether the bolt tightening torque meets the standard requirements (usually 40 - 60N&m
Oliver Watts
07/01/2025
What aspects need attention during the installation of dry-type transformers?
What aspects need attention during the installation of dry-type transformers?
1 Pre - installation PreparationAs a front - line installer, I know very well that the preparation work before installing a dry - type transformer must be thorough. First, I will carefully review the design drawings and technical documents, and check one by one the technical parameters such as the model specification, rated capacity, and voltage level of the transformer to ensure they are in full compliance with the design requirements. Then, I will conduct an unpacking inspection of the transfo
James
07/01/2025
What are the causes of dry-type transformers burning out during operation?
What are the causes of dry-type transformers burning out during operation?
1 Fault PhenomenonI am engaged in front - line fault maintenance work, and recently encountered problems with dry - type transformers. Dry - type transformers have a simple structure, are convenient for transportation, and easy for maintenance. They are widely used in power distribution places with relatively high environmental protection requirements. Because of their good fire - resistance, they can be installed in load - center areas to reduce voltage loss and power loss.The property manageme
Felix Spark
07/01/2025
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
Method for Automatic Isolation of Customer Equipment Faults by Load Switches in Distribution Networks
1 OverviewDistribution network safety has long been under - addressed, with its automation lagging substation automation . Using 10 kV intervals of existing substations to set line section points meets future grid needs . Configuration of distribution switches, section switches, and protection must match substation outgoing - line protection for reliability. Fault isolation, self - healing, and restoration are key to distribution automation .Scholars have studied smart distribution network fault
Felix Spark
06/30/2025
×
Inquiry