• 40.5kV HV Gas circuit breaker
40.5kV HV Gas circuit breaker
discuss personally
Model
LW36-40.5(W)/T4000-50
LW36-40.5(W)/T4000-40
LW36-40.5(W)/T3150-40
LW36-40.5(W)/T2500-40
LW36-40.5(W)/T2500-31.5H
Basic info
Brand Wone
Model NO. 40.5kV HV Gas circuit breaker
Rated voltage 40.5kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 50kA
Series LW36-40.5
Product Detail

Product introduction

LW36-40.5 outdoor self-energy HV AC SF6 circuit breaker is an outdoor three-phase HV AC equipment used in electricity grids with altitudes of no more than 3000m, environment temperatures of no less than -40℃, local pollution classes of no higher than Class IV, and AC 50Hz/60Hz with maximum voltage of 40.5kV, it is suitable for the control and protection of HV supply and transformation lines in power station, converting stations, and industrial and mining enterprises. it can also be used as connection circuit breaker.

Main characteristic

LW36-40.5 self-energy HV SF6 circuit breaker is equipped with advanced hot-expansion plus auxiliary pressure gas self-energy arc extinguishing technology and matched with new-type spring actuating mechanism, it has features such as long electrical endurance, small operating power, high electrical and mechanical reliability, high technical parameters, and moderate price. Lt’s main performance features are as follows:

1、High rated technical parameters: rated current 2500A/4000A and rated short circuit breaking current 31.5KA/40KA/50KA.suitable for the opening and closing of large-capacity electricity grids.

2、High electrical reliability

No-load line charging breaking ability and no-load cable charging breaking ability 50/60Hz dual-frequency C2,back-to-back capacitor bank breaking ability 50/60Hz dual-frequency C2, no re-breakdown;

Strong external insulation ability;, suitable for regions with 3000m of altitude or Class lV pollution.

3、High reliability of operating mechanism:

Mechanical endurance: separating and closing for 10000 times without replacing parts; can meet the user' s requirement of continuous running and little maintenance.

New type spring actuating mechanism has few components parts; overall high-strength cast aluminum frame and brake separating and closing spring; and centralized arrangement is adopted for the buffer, compact structure, reliable operation, low noise, and convenient maintenance; suitable for frequent operations.

4、Al exposed parts are made of stainless steel materials or hot-galvanized on the surface for high corrosion resistance.

5、Reliable sealing structure ensures the product annual leakage rates≤0.5%.

6、Four internally attached current mutual inductors for every phase can be installed on the circuit breaker. Microcrystal alloy and high permeability material are adopted for internally attached current mutual inductors. The accuracy of 200A and above current mutual inductors can reach up to Level 0.2 or 0.2S. Reliable electrical screening design is adopted for the cable coils of internally attached current mutual inductors to improve the electric field distribution of the mutual inductors and promote the internal insulation of the product. it can withstand 120kv and 5min working frequency withstand voltage test and the internal insulation is not interfered by the short circuit breaking working conditions, which makes it safe and reliable.

Main technical parameters

1732519731006.png

Order notice 

Model and format of the circuit breaker.

Rated electrical parameters (voltage, current, breaking current, etc.);

Environmental conditions for using (environment temperature, altitude, and environment pollution level);

Rated control circuit electrical parameters (power-storage electromotor rated volage and brake separating and closing cable coil rated voltage);

Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

The wire connecting direction of the primary upper terminal.

 


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
Analysis of the Safety and Reliability Assurance of Medium-Voltage Switchgear
As a professional engaged in power system operations, I recognize that medium-voltage (MV) switchgear plays a pivotal role in power distribution, metering, and protection. Ensuring its operational safety and reliability is critical—any malfunction can severely disrupt the entire power system. To enhance reliability, we must prioritize design-level optimizations, enabling MV switchgear to fulfill its functions and safeguard grid stability.1. Definition of Medium-Voltage SwitchgearIn my prac
Felix Spark
06/10/2025
What should be noted when using indoor vacuum circuit breakers?
What should be noted when using indoor vacuum circuit breakers?
I. Overvoltage PreventionVacuum circuit breakers excel in interrupting performance, but high overvoltage may occur across inductors during the switching of inductive loads due to abrupt changes in loop current, which requires special attention. When switching small-capacity motors, starting currents are large, so measures like step-down starting should be adopted to limit the current.Transformers with different structures show distinct characteristics: oil-immersed transformers have high impulse
Echo
06/10/2025
The application of indoor high-voltage vacuum circuit breakers
The application of indoor high-voltage vacuum circuit breakers
In the first half of 2007, as project participants from the Electromechanical Equipment Company of Huaibei Mining Group, we carried out a technical transformation of the 10kV substation in the East Factory Area. Our primary task was to replace the original 10kV disconnector - oil - immersed circuit breaker units with ZN20 indoor high - voltage vacuum circuit breakers.Previously, the SN10 - 10 oil - immersed circuit breakers had been in operation for an extended period, leading to severe oil leak
Echo
06/09/2025
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
What are the common faults and corresponding solutions for indoor drawer-type high-voltage vacuum circuit breakers?
Inability to Push In or Withdraw the Draw-out CarriageThe main manifestation is difficulty in inserting the carriage, which may cause equipment damage and threaten production when severe. The causes and countermeasures are shown in Table 1.The circuit - breaker fails to close. It manifests as the closing core actuating but the circuit - breaker not closing successfully; or the closing core not actuating, which shows that the control circuit of the circuit - breaker is open - circuited or the mec
Felix Spark
06/09/2025
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
What are the common faults and handling methods of the operating mechanisms of 35kV and 10kV indoor vacuum circuit breakers?
In power system operation and maintenance, we have found that 35kV and 10kV indoor vacuum circuit breakers, as core primary equipment of high-voltage switchgear, are widely used in main grid and user substations due to their high reliability and low maintenance workload. From daily inspections and live detection to routine maintenance, vacuum circuit breakers always remain our key focus, as their operational quality is directly related to the stability and reliability of the power system. This p
Felix Spark
06/09/2025
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Analysis of the Impact of Vacuum Arc Chamber Inspection and Maintenance on Improving the Reliability of Vacuum Circuit Breakers
Vacuum circuit breakers are widely used in distribution networks. As core components of power supply equipment, their performance hinges on both vacuum interrupters’ capabilities and circuit breakers’ mechanical characteristics (contact opening distance, stroke, pressure, average closing/opening speed, closing bounce time, opening - closing asynchronism, operation times, and cumulative allowable wear of contacts). Both are critical for reliable operation. The vacuum interrupter is th
Oliver Watts
06/09/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!