• 107kWH-232kWH Box integrated Energy Storage System(ESS)
107kWH-232kWH Box integrated Energy Storage System(ESS)
$264000.00
Model
JASS-100-215KF
JASS-50-107KF
JASS-100-232KL
JASS-500-1M
Basic info
Brand Wone
Model NO. Box integrated ESS
Cooling mode Forced air cooling
Rated Output Rating 100kw
Energy storage capacity 215kWh
Series Industrial&Commercial energy storage
Product Detail

Peculiarity

  • Modular energy storage converter parallel design concept, improve system stability, easy installation and maintenance, easy expansion.

  • Battery pack is replaceable, can be adapted to a variety of batteries, for different batteries to achieve different charging and discharging strategies; Low operation and maintenance cost.

  • Energy scheduling can be regulated, and users can change the charge and discharge logic according to the power consumption policy of different periods in the region.

  • Power factor can be adjustable, can achieve active power, reactive power independent control, to meet the needs of different loads.

  • Energy balance management controller is used to refine the energy management of the energy storage system to the battery PACK level.

  • Battery PACK level energy balance management controller to avoid capacity loss caused by mismatch.

  • Support the mix of old and new batteries, so that recharge phased deployment.

  • Outdoor modular energy storage converter cabinet design, high power density, easy maintenance.

Technical parameter

image.png

image.png

How does the battery management system in ESS protect against short circuits?

Identify short-circuit situations.

  • Current detection:The BMS identifies short-circuit conditions by continuously monitoring the current changes of the battery pack. When an abnormally high current is detected, a short circuit may have occurred.

  • Voltage monitoring:In the case of a short circuit, the voltage of the affected battery cell or the entire battery pack may suddenly drop. The BMS identifies this abnormal situation through vltage monitoring.

  • Temperature monitoring:A short circuit will cause a sharp rise in local temperature. The BMS detects abnormal temperature rises through temperature sensors to determine whether a short circuit has occurred.

Implement protection measures.

  • Cut off power supply:When a short circuit is detected, the BMS will immediately cut off the connection between the battery pack and the external circuit through relays or switches to prevent the current from continuing to flow and avoid excessive discharge or heating of the battery.

  • Alarm and record:Trigger the alarm system to send a warning signal to the operator and record relevant information such as the time and location of the short circuit occurrence for subsequent investigation and handling.

  • Isolate faulty units:If the short circuit occurs in a certain battery cell rather than the entire battery pack, the BMS can isolate the cell to prevent it from affecting other normal battery cells.



Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放