• 1100kV UHV SF6 Circuit Breaker
1100kV UHV SF6 Circuit Breaker
discuss personally
Model
LW10B-1100/4000-63
Basic info
Brand Wone
Model NO. 1100KV/4000A SF6 Circuit Breaker
Rated voltage 1100KV
Rated normal current 4000A
Series LW10B
Product Detail

Description:

SF6 circuit-breaker is a double-column four-fracture form, with a shunt capacitor and a closing resistor at interrupter chamber breaks; The circuit-breaker has compact structure, small arc extinguishing chamber, high contact speed, stable and reliable performance, long service life and high comprehensive technical and economic index.

SF6 circuit-breaker is outdoor three-phase AC 50Hz UHV transmission equipment, which is used to control, measure, protect and switch transmission lines in the power system with a rated voltage of 1000 kV. It can also be used to meet the capacitive current of the filter bank and capacitor bank to realize the control and protection of the filter bank and capacitor bank. The circuit-breaker is equipped with ABB HMB-8.12 compact spring hydraulic operating mechanism for division, closing and automatic reclosing. Each column has an independent hydraulic system, which can be operated in separate phases to realize single-phase automatic reclosing. Through the electrical linkage can also be three-phase linkage operation to achieve three-phase automatic reclosing.


Main Features:


  • Double column four fracture form, interrupter chamber fracture parallel capacitor and closing resistor, Cut back on oil.

  • The mechanical reliability of the product is good, to ensure the mechanical life of 10,000 times.

  • The circuit breaker structure is compact, the arc extinguishing chamber is small, the contact movement speed is high, the performance is stable and reliable, the service life is long, the comprehensive technical and economic indicators are high.

Technical parameter:


1719906238272.png

What kind of situation is the SF6 circuit breaker used?

Temperature Control:

  • Control the temperature of the installation environment to avoid adverse effects on the breaker's performance due to excessively high or low temperatures.

  • Avoid installing the breaker in locations exposed to direct sunlight or experiencing extreme temperature fluctuations.

Moisture Prevention Measures:

  • Implement moisture prevention measures to prevent water from entering the interior of the breaker, which can affect insulation performance and the normal operation of mechanical components.

  • Regularly inspect and clean the area around the equipment to remove dust and contaminants, preventing them from affecting the device's performance.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
Fault Analysis and Remedial Strategies for Reclosers in Vietnam's 20kV Coastal Grid
1. IntroductionIn Vietnam's coastal regions, 20kV reclosers play a critical role in maintaining power supply reliability amid harsh environmental conditions. These devices, compliant with IEC 62271-111 and Vietnam's national standard TCVN, are frequently exposed to salt fog, high humidity, and typhoons, necessitating robust fault management strategies. This article explores typical malfunctions of IP67-rated reclosers in Vietnam and proposes integrated solutions to enhance grid resilience.2. Env
Felix Spark
06/03/2025
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
Design and Application of High-Voltage Reclosers: Focusing on 20kV Systems in Indonesia and Vietnam
1. IntroductionIn the modern power grid infrastructure, high - voltage reclosers play a pivotal role in enhancing the reliability and efficiency of power supply. This is particularly crucial in regions like Indonesia, which has a vast and complex power distribution network spanning numerous islands, and Vietnam, with its developing coastal power systems. The 20kV voltage level, falling within the medium - high - voltage range, is widely adopted in urban grids, industrial power supply, and certai
Dyson
06/03/2025
What is a Per Unit System?
What is a Per Unit System?
Per-Unit System in Electrical Machine AnalysisFor the analysis of electrical machines or their systems, diverse parameter values are often required. The per-unit (pu) system provides standardized representations for voltage, current, power, impedance, and admittance, streamlining calculations by normalizing all values to a common base. This system is particularly advantageous in circuits with fluctuating voltages, where it simplifies cross-referencing and analysis.DefinitionThe per-unit value of
Edwiin
06/03/2025
Equivalent Circuit of a Transformer
Equivalent Circuit of a Transformer
The equivalent circuit diagram of any device can be extremely useful for predicting how the device will behave under different operating conditions. It is essentially a circuit - based depiction of the equations that describe the device's performance.The simplified equivalent circuit of a transformer is constructed by representing all of the transformer's parameters on either the secondary side or the primary side. The equivalent circuit diagram of the transformer is presented below:Let the equi
Edwiin
06/03/2025
What is the automatic recloser fault diagnosis technology?
What is the automatic recloser fault diagnosis technology?
According to statistics, the vast majority of overhead line faults are "transient", with permanent faults generally accounting for less than 10%. Currently, for 10kV distribution network lines, the combined use of automatic reclosers and sectionalizers can quickly restore power supply after a transient fault and isolate the faulty line section in case of a permanent fault. It is necessary to monitor the operating status of the automatic reclosing controller to enhance its operational reliability
Echo
06/03/2025
The Application of Reclosers and Sectionalizers in Distribution Network Automation
The Application of Reclosers and Sectionalizers in Distribution Network Automation
1. Selection of Reclosers and SectionalizersThe selection of reclosers and sectionalizers is crucial for achieving distribution network automation. Sectionalizers cooperate with the upstream circuit breakers on the power supply side. They automatically trip when three conditions are simultaneously met: the fault current exceeds its set - value, the line undervoltage current is less than 300 mA, and the set number of counts is reached. Reclosers are applied in indoor substations or on outdoor pol