Why is the starting torque of an induction motor higher, and what are its reduction techniques?
Reasons for High Starting Torque High Starting Current: During startup, an induction motor draws a high starting current, typically 5 to 7 times the rated current. This high current increases the magnetic flux density, resulting in a higher starting torque. Low Power Factor: At startup, the motor operates at a low power factor, meaning that most of the current is used to establish the magnetic field rather than producing useful torque. Design Characteristics: To provide sufficient torque during