Ⅰ. Technical Focus: Traceability to Metrological Standards
This solution centers on the national electric energy metrology reference system, employing an independently controlled traceability chain to ensure voltage measurement results are directly traceable to the International System of Units (SI). By eliminating cascading errors inherent in traditional measurement devices, it delivers reference-grade voltage measurement capabilities for advanced laboratories.
Ⅱ. Core Technical Innovations
Dual-Stage Voltage Transformer Error Compensation Structure
• Utilizes a dual closed-loop design with primary + compensation windings, dynamically offsetting excitation current and leakage reactance effects through real-time reverse magnetic flux cancellation. This surpasses the theoretical accuracy limits of single-stage transformers.
• Compensation winding accuracy: ±0.5 ppm, enabling automatic nonlinear error correction across a wide range (1%–120% Un).
Ⅲ. Application Scenarios
• National metrology institute voltage standards
• Power monitoring for chip manufacturing equipment (e.g., 0.1nm-resolution etchers)
• Precision certification of magnetic confinement power supplies in fusion devices
• Reference resistivity measurements for novel semiconductor materials