YH-5W-6
YH-5W-24
YH-5W-15
YH-5W-6
Basic info
Brand Wone
Model NO. Zinc oxide surge arrester for lightning protection
Rated voltage 15kV
Continuous operating Voltage 12.75kV
Series Surge Arrester
Product Detail

Description:

Zinc oxide surge arrester is a lightning protection device with superior protection performance, light weight, pollution resistance and stable performance. It mainly uses the good non-linear volt-ampere characteristics of zinc oxide to make the current flowing through the surge arrester at normal working voltage very small (microamp or milliampere level); when the overvoltage acts, the resistance drops sharply,venting the overvoltage Energy to achieve the effect of protection. The difference between this kind of lightning arrester and the traditional lightning arrester is that it has no discharge gap, and uses the non-linear characteristics of zinc oxide to discharge and break.

General :

  • Ratings:0.22-500KV (porcelain),0.22-220KV(composite)

  • Application.for protection of power transmission& distribution system from over-voltage.

Features:

  • Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.

  • Easy installation and maintenance.

  • Good sealing capability to ensure reliable operation.

  • Protection and reliability of the surge arrester have been greatly enhanced.

Type designation:

image.png

Working condition:

  • Ambient air temperature:-40℃—+40℃.

  • Altitude: <=2000m.

  • Frequency: 48Hz~62Hz.

  • Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter.

  • Earthquake intensity is less than 8 degree.

  •  Max. Wind speed is 35m/s.Aawifflii Surge arrester.

Main techical parameter:

Metal oxide Polymer Housing (Gapless)type Surge Arrester for A.C System(5kA series)

企业微信截图_17339000416849.png

企业微信截图_17339001468386.png

 Metal Oxide Polymer Housing (Gapless) type Surge Arrester tor A.C. System (10KA series)

企业微信截图_17339003233255.png


Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

企业微信截图_17339005212737.png

Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)

企业微信截图_17339007891245.png

Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

image.png

企业微信截图_17339011202607.png


Metal Oxide Polymer Housing (Gapless)type Surge Arrester for A.C. System (20KA series)

企业微信截图_1733901352801.png

When order,please indicate the detailed information as below listed:

  • Anti-contamination degree and creepage distance.

  • Any special requirement.

  • Accessories.

  • Max. System voltage.

  • Rated voltage or Max.continuous operating voltage.

  • Nominal discharge current.

  • Type of housing material.

How does the zinc oxide arrester for lightning protection work?

Normal Operating Voltage:

  • Under normal operating voltage, the zinc oxide varistor discs present a high-resistance state, allowing only a minimal current—typically in the microampere or milliampere range—to flow through the surge arrester. At this time, the arrester acts like an insulator, having virtually no impact on the system's normal operation.

Overvoltage Event:

  • When struck by lightning or when overvoltage occurs in the system (such as from lightning surges or switching overvoltages), the resistance of the zinc oxide varistor discs drops sharply, forming a low-resistance path. This allows the energy generated by the overvoltage to rapidly discharge through the arrester into the ground, thereby limiting the voltage on the protected equipment to within a safe range and effectively protecting the insulation of electrical devices from overvoltage damage.

Post-Overvoltage Recovery:

  • Once the overvoltage event has passed, the zinc oxide varistor discs quickly return to their high-resistance state, restoring normal power supply to the system and preparing for any potential future overvoltage events.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Operational Analysis of Prefabricated Enclosure Substations in Extreme Cold Climate Applications
Under global climate diversity, alpine power construction faces technical and environmental challenges. Extreme climates, complex geology, and long - term low winter temperatures, along with ice, snow, and storms, strain electrical equipment stability and power facility construction (schedule, cost, maintenance). Traditional on - site substations, with long construction and poor adaptability, can’t meet alpine regions’ fast, stable power needs.Prefabricated cabin substations, as modu
Echo
06/13/2025
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives
Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).To address their pros/cons, ring - network prefabricated ones were developed.I. Basic Materials for Prefabricated Compact Substation BoxesMaterials need hardness, strength,
Echo
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放