Model
Trihal 12/17.5/24/36kV
Basic info
Brand Schneider
Model NO. Trihal Cast resin transformer up to 36kV
Rated voltage 12/17.5kV
Series Trihal
Product Detail

Product at a glance

Cast resin, 50 Hz, three-phased distribution transformers with the following characteristics:

  • Indoor use / Outdoor use with properly designed enclosure
  • Thermal class F - Temperature rise 100
  • Ambient ≤ 40°C, altitude ≤ 1000 m
  • MV windings encapsulated in cast resin
  • Pre-impregnated LV windings
  • Natural air cooling system (AN type)
  • Core and frame covered with protective coating
  • Anti-corrosion surface treatment : corrositivity category class C2, “Medium” durability (according to ISO 12944-2)

 

The components of the products

 

 

Compliance:
These transformers comply with standards:

  • IEC 60076-11
  •  EN 50588-1

Schneider Electric guarantees that its transformers are silicone free and certified:

  •  C3* Climatic class
  •  E3 Environment class according to IEC 60076-16
  • F1 Fire behaviour class
  • Almost partial discharge free -Acceptance level:
  • ≤ 10 pC Routine Test
    - ≤ 5 pC Special Test according to IEC 60076 standard
    * C2 Thermal shock test carried out at -50°C

 

Trihal
Up to 3150 kVA, 12 kV, losses

Main electrical characteristics 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

 

Trihal
Up to 3150 kVA, 17.5 to 24 kV, losses

Main electrical characteristics 

 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

Trihal
Up to 3150 kVA, 36 kV, losses

Main electrical characteristics 

 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

All available Trihal technical range

 


Trihal
Options and accessories 

High voltage surge arresters

If the installation is likely to be subjected to overvoltage of any kind (atmospheric or switching), the transformer must be protected by phase-to-earth surge arresters, installed directly on the transformer’s HV connection terminals (either at the top or the bottom).
It is essential to install these surge arresters:

  •  where the lightning impact level Nk is greater than 25. The risk of direct or induced atmospheric overvoltage is directly proportional to Nk
  •  during occasional switching (less than 10 operations a year) of a transformer with a weak load, or during a magnetization phase. It is also highly recommended to install them: where the substation is supplied by a network including overhead parts, then a
    cable longer than 20 m (case of an overhead-underground network) Surge arresters can be installed in an IP 31 enclosure, or even on existing equipment, provided that insulation distances are adhered to. 

                            High voltage surge arresters on the lower part

 

 

Vibration damping
Roller anti-vibration pads
This accessory, placed under the rollers, avoids vibrations being transmitted from the transformer to its environment.
Damper unit
This device is installed instead of the roller and enables transmission of vibrations to the transformer environment to be attenuated.

 

 

            Anti-damping accessories 

 

Protective Enclosure

The IP and IK protective indices refer to the following criteria:

IP protection indices

 

          Protective enclosure IP31, IK7

 

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High voltage/Low voltage
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
9 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放