• Single-phase Smart Energy Meter
  • Single-phase Smart Energy Meter
Single-phase Smart Energy Meter
$100.00
Model
GSD7666-WJ3
Basic info
Brand Wone
Model NO. Single-phase Smart Energy Meter
Rated normal current 100A
Analogue input type External CT
Communication port support RF
Number of outputs 1 pulse
Number of inputs 1
Multi-tarff 4 tariffs
Current transformer Yes
Series GSD7666-WJ3
Product Detail

Description

GSD7666- WJ3 is an advanced single-phase multi-function smart meter used to measure energy accurately for commercial & residentialcus tomers,with a wide range of functions,smart measurement & flexible  communic ation modules for remoter eading & management.It could be used for either prepayment (compliant with STS standard) or postpayment applic ations (optional).

Feature

  • Dual - relay .

  • Multi-tariff .

  • DLMS/ COESM compliant.

  • Infrared port/RS485.

  • Tamper detection & recording.

  • LCD display capable of reading without power.

  • Protection cover for infrared port(optional).

  • ·Active/reactive energy measurement .

  • Double CT for phase & neutral line. 

  • Disconnecting on overload & no-credit condition .

  • Prepayment/postpayment mode switchable.

  • Display scroll button or STS keypad(optional) .

  • Programmable warning of load limit & low credit.

Specifications

Main
Range GSD
Model NO. GSD7666-WJ3
Product or Componet Type Energy meters
Country of origin China
Complementary
Phase Single-phase
Type of measurement

Active power;current

voltage;Active power

Metering type

Active,

reactive, 

apparent energy (signed, four quadrant)

Device Application Multi-tariff
Accuracy class

Class1.0  active energy IEC62053-21

Input type ---
Rated voltage 230V
Network Frequency 50~60Hz
Technology Type Electronic
Display Type LCD display
Sampling rate ---
Maximum value measured -----
Tariff input Tariff 4
Communication port protocol ---
Communication port support PLC/GPRS/3G/4G/RF
Local signalling Green indicator light power ON
Yellow flashing LED accuracy checking
alarm overload
Number of inputs ---
Number of Outputs ---
Output voltage ---
Mounting Mode ---
Mounting Support Normal
Connections - terminals Maximum cable size 8mm
Standards

IEC62053-21

Environment
IP degree of protection P54
Ambient air temperature for operation -25℃~+70℃- IEC
Ambient Air Temperature for Storage -40℃~+85℃
Dimensions 120*68*29/184*122*64
Packing Units
Unit Type of Package 1 PCE
Package 1 Height
Package 1 Width
Package 1 Length
Package 1 Weight


Dimension



image.png

image.png

image.png

image.png








Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Application of Prefabricated Substation Enclosures in Utility-Scale PV Plants at High Altitudes
Application of Prefabricated Substation Enclosures in Utility-Scale PV Plants at High Altitudes
In recent years, driven by policies and the enabling environment, the domestic new energy industry has achieved rapid development. A large number of photovoltaic (PV) projects have been introduced into the power market, and high-altitude PV projects are among them. If prefabricated cabin substations can be utilized scientifically and rationally, high-altitude PV projects can feature short construction cycles, quick commissioning, and relatively low investment levels. This is of great significanc
Echo
06/14/2025
Research and Application of Prefabricated Enclosure Structure for High-Voltage Compartments in Substations
Research and Application of Prefabricated Enclosure Structure for High-Voltage Compartments in Substations
The economic development demands higher efficiency in substation construction, giving rise to prefabricated cabin substation technology. With modular design, equipment wiring, commissioning, and prefabrication are completed in factories, requiring only "building-block" assembly on-site. Take the 10kV prefabricated high-voltage room as an example: equipment and cabin are installed in the factory, with on-site work limited to busbar and cabin assembly. The main transformer incoming line connects v
Echo
06/14/2025
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
Modular Intelligent Substation - Prefabricated Secondary Switchgear Integration Assembly
With the development of the national economy and society, the requirements for the quality and craftsmanship of power grid projects have become increasingly stringent. The need to improve the construction progress and quality of substations has created opportunities for the promotion of prefabricated cabin - type intelligent substations. The traditional on - site wiring and commissioning of secondary substation equipment involve a large amount of work. Moreover, on - site construction has to wai
Echo
06/13/2025
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Application of Pre-integrated Prefabricated Substations in Renewable Energy Sector
Against the backdrop of profound changes in the global energy landscape and the booming development of the new energy industry, the construction mode of traditional substations struggles to meet the rapid deployment needs of new energy projects. The modular intelligent prefabricated cabin substation, leveraging its innovative advantages, has become a key direction for optimizing the new energy power system. In - depth exploration of its technical principles, industry adaptability, and applicatio
Echo
06/13/2025
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations
1 Implementation Strategies for the Scheme1.1 Deepen Survey and ResearchBefore constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.1.2 Strengthen Structural ConstructionDuring promotion, multi - dim
Echo
06/13/2025
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
Comparative Analysis of 500 kV Prefabricated Substations vs. Conventional Substations
The secondary equipment area of conventional substations uses reinforced concrete or prefabricated steel structures, facing issues like long construction cycles, unreasonable functional zone design, strict environmental assessments, dust, noise, and disturbances. Primary and secondary equipment can only be installed after civil works and decoration, lowering construction efficiency.Prefabricated cabin substations integrate modularity, intelligence, and cost - effectiveness, boasting green, energ
Dyson
06/13/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放