• RCW-S21.9M 21.9kV MV outdoor vacuum recloser
RCW-S21.9M 21.9kV MV outdoor vacuum recloser
$5000.00
Model
RCW-S21.9M/1250-25C
RCW-S21.9M/1250-25
RCW-S21.9M/800-20C
RCW-S21.9M/800-20
RCW-S21.9M/630-16C
RCW-S21.9M/630-16
RCW-S21.9M/400-12.5C
RCW-S21.9M/400-12.5
Basic info
Brand ROCKWILL
Model NO. RCW S21.9M MV outdoor vacuum recloser
Rated voltage 21.9kV
Rated normal current 1250A
Rated short circuit breaking current 25kA
Power frequency withstand voltage 70kV/min
Rated lightning impulse voltage 170kV
manual closing Yes
Series RCW
Product Detail

Description:

The RCW   series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60Hz power system.  and it’s rated current can reach 1250A.The RCW   series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.The RCW   series vacuum recloser is mainly combined with integration terminal, current transformer, permanent magnetic actuator and it’srecloser controller.

Features:

  • Optional grades available in rated current range.

  • With optional relay protection and logic for user selection.

  • With optional communication protocols and I/O ports for users to choose.

  • PC software for controller testing, setup, programming, updates.

Parameters:

image.png

image.png

External dimensions

企业微信截图_17105494892828.png

Environmental requirement

image.png

Product show

What are the insulation faults of outdoor vacuum reclosers and their solutions?正方型 单相.png

Insulation Faults:

Insulator Flashover:

  • Clean Insulators: For insulators that experience flashover due to surface contamination, regular cleaning is necessary. Specialized insulator cleaning tools, such as insulator cleaning brushes or high-pressure water guns, can be used. After cleaning, anti-flashover coatings can be sprayed on the insulator surfaces to enhance their contamination resistance.

  • Replace Insulators: If insulators show a decrease in insulation strength due to lightning strikes or other reasons, and exhibit obvious cracks or damage, they should be replaced promptly. When replacing insulators, choose ones that meet the voltage and mechanical strength requirements of the equipment.

Insulation Aging:

  • Test Insulation Performance: Use insulation resistance testers, dielectric loss testers, and other equipment to regularly test the insulation performance of insulating materials. When a decline in insulation performance is detected, analyze the causes of aging.

  • Replace Insulation Components: If insulation aging is severe, such as when partial discharge phenomena are observed, aged insulation components (e.g., insulating bushings, insulating supports) should be replaced promptly. Additionally, improve the operating environment of the equipment, such as by enhancing ventilation and reducing humidity, to slow down the aging process of the insulation.

Insulation Faults Resolution:

Insulator Flashover:

  • Clean Insulators: For insulators that experience flashover due to surface contamination, regular cleaning is necessary. Specialized insulator cleaning tools, such as insulator cleaning brushes or high-pressure water guns, can be used. After cleaning, anti-flashover coatings can be sprayed on the insulator surfaces to enhance their contamination resistance.

  • Replace Insulators: If insulators show a decrease in insulation strength due to lightning strikes or other reasons, and exhibit obvious cracks or damage, they should be replaced promptly. When replacing insulators, choose ones that meet the voltage and mechanical strength requirements of the equipment.

Insulation Aging:

  • Test Insulation Performance: Use insulation resistance testers, dielectric loss testers, and other equipment to regularly test the insulation performance of insulating materials. When a decline in insulation performance is detected, analyze the causes of aging.

  • Replace Insulation Components: If insulation aging is severe, such as when partial discharge phenomena are observed, aged insulation components (e.g., insulating bushings, insulating supports) should be replaced promptly. Additionally, improve the operating environment of the equipment, such as by enhancing ventilation and reducing humidity, to slow down the aging process of the insulation.



Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
The design of the three-purpose grounding transformer
The design of the three-purpose grounding transformer
Underground Power Cable Transmission LinesDirect - buried power cable lines have large ground - distributed capacitance, causing high single - phase - to - ground short - circuit capacitive current. For 10 kV lines, if this current exceeds 10 A, arcs hardly self - extinguish, risking arc overvoltage and endangering line equipment. Arc extinction is thus necessary. With a Dyn - connected main transformer, an arc - suppression coil on the secondary neutral point suffices. For Yd - connected ones,
Dyson
06/12/2025
Failure Analysis and Design Optimization of Conventional Grounding Transformers
Failure Analysis and Design Optimization of Conventional Grounding Transformers
I. Core Cause of Damage: Electrodynamic Impact (Complying with GB/T 1094.5 / IEC 60076-5)The direct cause of high-voltage winding end collapse is the instantaneous electrodynamic impact induced by short-circuit current. When a single-phase grounding fault occurs in the system (such as lightning overvoltage, insulation breakdown, etc.), the grounding transformer, as the fault current path, withstands high-amplitude and steep-rise-rate short-circuit currents. According to Ampère's force law
Felix Spark
06/12/2025
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
Analysis of Grounding Transformer Operational Behavior Under System Single-Phase-to-Ground Fault Conditions
1 Theoretical AnalysisIn distribution networks, grounding transformers serve two key roles: powering low - voltage loads and connecting arc - suppression coils at neutrals for grounding protection. Grounding faults, the most common distribution network fault, heavily impact transformers’ operating characteristics, causing sharp changes in electromagnetic parameters and status.To study transformers’ dynamic behaviors under single - phase grounding faults, build this model: Assume a tr
Felix Spark
06/12/2025
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
Design Calculations for Neutral Grounding Schemes and Grounding Transformer Sizing in Utility-Scale Solar PV Plants
1 Classification of Neutral Grounding Methods for Solar Photovoltaic Power StationsInfluenced by differences in voltage levels and grid structures across regions, the neutral grounding methods of power systems are mainly categorized into non-effective grounding and effective grounding. Non-effective grounding includes neutral grounding via arc suppression coils and neutral ungrounded systems, while effective grounding comprises neutral solid grounding and neutral grounding via resistors. The sel
Dyson
06/12/2025
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
Zero-Sequence Impedance Characterization of Dry-Type Grounding Transformer with ZN Connection
In a neutral-insulated three-phase power system, an earthing transformer provides an artificial neutral point, which can be solidly earthed or earthed via reactors/arc suppression coils. The ZNyn11 connection is typical, where zero-sequence magnetomotive forces in the inner/outer half-windings of the same core column cancel out, balancing fault currents in series windings and minimizing zero-sequence leakage flux/impedance.Zero-sequence impedance is critical: it determines fault current magnitud
Dyson
06/12/2025
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
Case Analysis on Maloperation of Grounding Transformer Overcurrent Protection Relay
The neutral grounding mode refers to the connection between the power system neutral point and ground. In China's 35 kV and below systems, common methods include ungrounded neutral, arc-suppression coil grounding, and small-resistance grounding. The ungrounded mode is widely used as it allows short-term operation during single-phase grounding faults, while small-resistance grounding has become mainstream for its fast fault removal and overvoltage limitation. Many substations install grounding tr
Felix Spark
06/12/2025
×
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
商品视频播放